AC power

WARNING! For protection from electric shock, the fixture must be grounded (earthed). The AC mains
supply must be fitted with a fuse or circuit breaker and ground-fault (earth-fault)
protection.
Important! Check that the correct fuse is installed before applying power.

Power supply and main fuse

The MAC 700 Profile features an auto-sensing switch-mode power supply that automatically adapts to
100-130 V and 200-250 V AC mains supplies. However, a suitable main fuse must be installed to match the
local AC mains supply. The MAC 700 Profile is supplied with two main fuses:
• a 6.3 AT fuse (installed) for use with AC supplies of 200 - 250 volts
• a 15 AT fuse (packed with user manual) for use with AC supplies of 100 - 130 volts
To install the correct fuse:
1. Disconnect the fixture from AC power.
2. Remove the main fuse holder, which is located beneath the power switch.
3. For operation on 200 - 250 VAC supplies, install the 6.3 A fuse. For operation on 100 - 130 VAC
supplies, install the 15 A fuse.

Power connection

Important! Connect the MAC 700 Profile directly to AC power. Do not connect it to a dimmer system;
doing so may damage the fixture.
You may need to install a cord cap (mains plug) that fits your supply on the power cable. A grounding-type
(earthed) plug must be installed following the manufacturer's instructions. Table 1 shows some possible pin
identification schemes; if the pins are not clearly identified, or if you have any doubts about proper
installation, consult a qualified electrician.
To apply power, first verify that the head tilt locks are released and then set the power switch on the base to
the "I" position.
Wire Color
Pin
brown
live
blue
neutral
yellow/green
ground (earth)
Table 1: Cord cap connections
Symbol
L
N
AC power
Screw (US)
yellow or brass
silver
green
7