Display messages

Message
RST (Reset)
SRST (Serial reset)
MERR - MEMORY ERROR
HTSE - HEAD TMP SEN ERR
LTSE - LAMP TEMP SEN ERROR
HTSE - HEAD TMP CUT OFF
LTSE - LAMP TEMP CUT OFF
FBEP - PAN FBACK ERR
FBET - TILT FBACK ERR
PSER - PAN SENSOR ERR
TIER - TILT SENSOR ERR
DRER - DRIVER CURR ERR
VOLT - VOLTAGE ERR
RAME - RAM ERROR
COLD - EFFECTS TOO COLD
FAN - FAN ERROR
COER - COLOR ERROR
CCER - COLOR CALIB ERR
Appears when...
... the fixture is indexing effects at startup.
... the fixture has received a reset command.
...the EEPROM memory cannot be read.
...there is a malfunction in the head
temperature sensor circuit.
...there is a malfunction in the lamp
temperature sensor circuit.
...the head temperature sensor measures that
head temperature is too high. Power to the
LEDs is cut off.
...the LED temperature sensor measures that
LED temperature is too high. Power to the
LEDs is cut off.
...there is a malfunction in the optical pan/tilt
monitoring circuit (e.g. sensor defective). After
a time-out, the effect in question stops in a
random position.
...there is a malfunction in the electrical
indexing circuit for pan, tilt or one of the
drivers. After a time-out, the fixture will
establish a mechanical stop, and continue to
work normally.
...there is a voltage or RAM error.
...the onboard thermostat measures that the
effects are too cold.
...there is a fan or fan driver error.
...there is a driver error.
...color calibration data is invalid or
communication error.
Table 4: Display messages
Display messages
What to do
Wait for reset to complete.
Wait for reset to complete. Note that
you can set PERSONALITY
DMX RESET to OFF to prevent
accidental DMX reset commands.
Reset fixture.
Contact Martin if problem persists.
Contact Martin service for assistance.
Contact Martin service for assistance.
Check that ambient temperature is not
too high.
Check that the fixture is clean.
Contact Martin service for assistance.
Reset fixture. Contact Martin service if
problem continues.
Reset fixture. Contact Martin service if
problem continues.
Reset fixture. Contact Martin service if
problem continues.
Leave fixture powered on to warm it up.
Contact Martin service if problem
continues or fixture is warm.
Check that fan on rear of head is free to
rotate freely.
Contact Martin service for assistance.
Contact Martin service for assistance.
Contact Martin service for assistance.