Display messages

Message
   (Reset)
    (Serial reset)
   
    
    (Lamp error)
    (Lamp explosion mode)
   
    (Memory error)
    (Short error)
    (Base temperature error)
    (Head temperature error)
    (Feedback error pan)
    (Feedback error tilt)
    (Feedback error pan & tilt)
    (Pan time-out)
    (Tilt time-out)
    (Cyan time-out)
    (Magenta time-out)
    (Yellow time-out)
    (CTC time-out)
    (Color wheel 1)
    (Color wheel 2/dimmer
wheel time-out)
    (Zoom time-out)
   
Appears when...
... the fixture is indexing effects at
startup.
... the fixture has received a reset
command from the controller.
... the effects have been indexed and are
moving to their default positions.
...the lamp access cover is not fully
closed.
... the lamp does not ignite within 10
minutes of receiving a 'Lamp ON'
command. Probable causes are lamp
missing/defective, or insufficient AC
voltage.
...the fixture has entered lamp explosion
mode because it has detected a lamp
failure. Pan and tilt are locked and DMX
control is disabled to minimize the risk of
falling lamp debris if the bulb has
shattered.
...there is a lamp temperature error.
...the EEPROM memory cannot be read.
... the fixture detects the lamp is on but
no 'Lamp ON' command has been
received. This can occur if the lamp relay
is stuck or if the lamp-power feedback
circuit fails. The fixture may be operated
but remote lamp on/off may be affected.
... there is a fault with the temperature
sensor in the base or head.
...pan, tilt, or both pan and tilt feedback
circuits are malfunctioning. It is still
possible to operate the fixture, although it
switches to "safe" mode with reduced
maximum speed, thus preventing the
fixture from losing track of its home
position (losing step).
...the electric indexing circuit is
malfunctioning. The fixture will, after the
time-out, establish a mechanical stop,
and continue to work normally.
...the barndoor rotation mechanism is
malfunctioning.
Table 2: Display messages
Display messages
What to do
Wait for reset to complete.
Wait for reset to complete. Set
   
   
  
to
accidental reset commands.
Wait a few moments.
Verify that the lamp access cover is
locked in place.
Check the lamp. Check that the
voltage and frequency settings match
the local supply.
Check the lamp. Pan and tilt are
released and DMX control is
re-enabled when power is reapplied.
   
Set fan speed to
using the
   
menu and restart the fixture.
Contact Martin service personnel if
problem persists.
Contact Martin service personnel for
assistance.
Contact Martin service personnel for
assistance.
Contact Martin service personnel for
assistance.
Contact Martin service personnel for
assistance.
Reset fixture. Contact Martin service
personnel if problem continues.
Reset fixture. Contact Martin service
personnel if problem continues.
to prevent
43