The following special limitations must be observed in order to maintain safety and electromagnetic
compatibility performance.
Power Connection
The console should only be operated with the power
supply connected to ground via the ground in the mains
connector.
Audio Connections
The console should only be operated with high quality
twisted-pair audio cables. All connector shells should be
of metal construction so that they provide a screen when
connected to the console. All jack connector shells should
be connected to the cable screen. All XLR plugs should
have pin one (1) connected to the cable screen.
INSTALLATION
Position
The position of the console will vary from venue to venue. However, when positioning the console for front of house usage it
is worth placing the console in a position where the sound system used can be heard properly from the mix position. Try to
avoid placing the console behind pillars or large objects , or mixing from a level above the speaker position (e.g. from a
balcony).
Also try to avoid placing the console near or on any power distribution units or power amplifiers.
Power
If using an external power supply, it should be located as far away from the console as the connecting cable will allow. The
power supply should be set for the voltage supply available in your area and plugged into the mains outlet using the cable
provided.
!
THE POWER SUPPLY SHOULD NEVER BE OPERATED WITH
Please note that the power supply contains LETHAL VOLTAGES greatly in excess of
To ensure the correct and reliable operation or your Midas Verona console, only high quality screened twisted pair
audio cable and metal bodied connectors should be used.
Female XLR
1
Pin 1 - Screen/Ground
3
Pin 2 - Hot Signal
2
Pin 3 - Cold Signal
Male XLR
2
3
Pin 1 - Screen/Ground
1
Pin 2 - Hot Signal
Pin 3 - Cold Signal
Note: Sockets are viewed from the front face.
Quarter Inch Jack
TRS Signal
Sleeve
Screen/Ground
Ring
Cold Signal
Tip
Hot Signal
THE MAINS EARTH DISCONNECTED
the mains voltage and that it's rails can produce extremely large currents which
could burn out equipment and wiring if shorted. All testing and servicing should
ONLY be carried out by a qualified engineer.
TRS Insert
TRS Headphone
Screen/Ground
Screen/Ground
Insert Return
Right
Insert Send
Left
Operators Manual - Page 6
Electric Fields
If the console is operated in an electromagnetic field that is
amplitude modulated by an audio frequency signal, the signal to
noise ratio may be degraded. Degradation of up to 60dB may be
experienced
under
extreme
modulation).
RCA (Tape In/Out)
Centre - Signal
Surround - Screen
The Venice's Tape In/Out sockets are
unbalanced and operate at a nominal
signal level of -10dBu.
Fo r
interference use metal bodied RCA plugs.
ATTENTION
conditions
(3V/m,
Connections
i n c r e a s e d
p r o t e c t i o n
90%
a g a i n s t