9) Remove 2 screws from unit.
10) Place grommet in rear plate through the
bottom of the opening as shown below.
Rear Plate
Grommet
11) Place the blower close to the base of the unit
and feed the wires through the grommet in
the rear plate.
Wires
This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged
directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.
®
Hampton
H15-1 Direct Vent Freestanding Gas Stove
12) Slide fan into place and secure with the two
screws removed in step 9.
13) Connect long black & red wires to thermodisc
and secure wires.
WARNING: Electrical Grounding Instructions
INSTALLATION
14) Connect fan ground wire to lug nut at base
of unit.
15) Before re-attaching the rear access panel,
the valve wires and the fan wires need to
be connected.
Re-connect the red and grey valve wires
removed in step 2.
Connect the black and white fan wires as
per the wiring diagram below.
16) Slide the Rear Access Panel back into posi-
tion and secure with 2 screws.
Lug Nut