8.4)
Ductwork
and Filter:
Installation:
Design and install air distribution system to comply with
Air Conditioning
Contractors
of America manuals or
other approved
methods that conform to local codes
and good trade practices.
When furnace supply ducts carry air outside furnace
area,
seal
return
air duct to furnace
casing and
terminate duct outside furnace space.
Install
air conditioning
cooling
coil (evaporator)
on
downstream side (in the supply air plenum) or furnace.
If separate evaporator and blower unit is used, install
good sealing dampers for air flow control. Cold air from
the evaporator
coil going through the furnace could
cause condensation and shorten furnace life.
I
CAUTION
Dampers
(purchased
locally)
MUST
be
automatic.
Poison carbon monoxide
gas hazard.
Do
NOT
draw
return
air
from
inside
a
closet
or utility
room.
Return
air duct
MUST be sealed to furnace
casing.
Failure to properly
seal duct can result
in
death,
personal
injury
and/or
property
damage.
Poison carbon
monoxide
gas hazard.
Install evaporator
coil on the supply side of
the furnace
ducting.
Evaporator
coil
installed
in
return
side
ducting
can
cause
condensation
to form
inside
heat
exchanger
resulting
in heat
exchanger
failure.
This
could
result
in
death,
personal
injury
and/or
property
damage.
18