a. Turnoff mainwatersupplyintothe structure and
drainthe waterlinesif possible.Openfaucetsin
appropriate areas.
b. Have someonecheck the structurefrequently
during coldweather t omakesureit iswarmenough
to prevent p ipes fromfreezing.Suggest t heycalla
qualified s ervice agency, i frequired.
2.3)
Installation
regulation:
Installation MUST conform with local building codes or
in the absence
of local
codes, with
the
National
Electrical
Code, ANSI/NFPA
No.70-1990
or current
edition and Installation of Oil Equipment, NFPA No.31.
3)
LOCATING
THE FURNACE
CAUTION
Check carefully
your furnace
upon delivery for
any
evidence
of
damage
that
may
have
occurred
during
shipping
and handling.
Any
claims
for damages
or lost parts
must
be
made with the Transport
Company.
3.1)
Location:
Locate the furnace
as closely
as possible
to the
chimney or vent terminal, providing ample clearance to
permit easy accessibility for cleaning the inside of the
furnace, the removal of filters, blower, motors, controls
and flue connections.
The furnace may be installed on
a combustible floor.
Do not install furnace directly on carpeting, tile or other
combustible material.
The furnace
must
be installed
level for safe quiet
operation.
CAUTION
Do
NOT
operate
furnace
in
a
corrosive
atmosphere
containing
chlorine,
fluorine
or
any other damaging
chemicals.
Refer to Part
1, section 5.2.
TABLE #1
Minimum Installation clearances from combustible materials (Chimney installation*)
"
"
NOUF160
Furnace
1"
Sides
Supply
plenum, warm air duct
1"
within 6 ft of furnace
Back
Furnace
18"
Top
Furnace casing or plenum
2"
Bottom
Furnace - combustible floor
0"
Front
Furnace
24"
* See Part 1 section 4.3 for Direct Vent application clearance.
OLR105 -OLF105.
NOLF105
•
OUF105 - NOUF105
1 "
1 "
1 "
1 "
0"
24"
4)
VENTING
4.1)
General:
The furnaces can be vented in several ways:
Chimney Vented:
Using the Beckett AFG or Riello 40-F
burner, the
furnaces
can be chimney
vented with or without a
barometric
damper.
The unit will be operated
at a
negative over fire draft and stack draft.
Poison
carbon
monoxide
gas,
fire
and
explosion
hazard.
Read
and follow
all instructions
in this
section.