11) MAIN CONT. VOLTAGE
Percentage of the total voltage of the battery applied to the main contactor
coil.
12) AUX OUTPUT VOLTAGE
Percentage of the total voltage of the battery applied to the Eb coil.
9.4.3 Main menu "PARAMETER CHANGE" functions list
To enter the MAIN MENU' it is just necessary to push the ENTER button from the
home display in the hand set.
1) Opening Zapi Menu
2) Press ENTER to go into the General Menu
3) The Display will show: PARAMETER CHANGE
4) Press ENTER to go into the Parameter
Change menu
5) The Display will show the first parameter
6) Press either ROLL UP and ROLL DOWN to
display the next parameter
7) The names of the Parameters appear on the
Display
8) When the desired Parameter appears, it's
possible to change the Level by pressing either
SET UP or SET DOWN buttons.
9) The Display will show the new level.
10) When you are satisfied with the result of the
changes you have made, press OUT.
11) The Display asks: "ARE YOU SURE?"
12) Press ENTER to accept the changes, or press
OUT to discard them.
Page - 44/86
NONE:
No CHECK UP NEENED warning
OPTION#1: CHECK UP NEENED warning shown on the hand set and
MDI after 300 hours
OPTION#2: Equal to OPTION#1 but Speed reduction after 340 hours
OPTION#3: Equal to OPTION#2 but the truck definitively stops after 380
hours
CA1S2B ZAPI 0.00
24V 350A 00000
' % '
' ' '
MAIN MENU
PARAMETER CHANGE
' % '
' ' '
ACC DELAY
LEVEL = 5
% ' '
% ' '
RELEASE BRAKING
LEVEL = 5
' ' %
' ' %
RELEASE BRAKING
LEVEL = 2
' ' '
' % '
ARE YOU SURE?
YES=ENTER
NO=OUT
' ' '
' % '
AEQZP0BA – COMBI AC1 - User Manual
Need help?
Do you have a question about the COMBI AC1 and is the answer not in the manual?
Questions and answers