11.8 Slave warnings overview
Related Master
Slave error code
error code
Current Sensor
Pump Warning
Low
Hw Fault Valve
Pump Warning
Valve Coil Shorted Pump Warning
Valve driver
Pump Warning
shorted
Valve Cont driver
Pump Warning
Evp Driver Ko
Pump Warning
Pump Stby I high
Pump Warning
Pump I=0 ever
Pump Warning
motor temperature Pump Warning
waiting for trac
ALARM XXX
incorrect start
Pump Warning
vacc not ok
Pump Warning
ram warning
Pump Warning
eep warning
Pump Warning
lift+lower
Pump Warning
eeprom ko
Pump Warning
Pump motor
Pump Warning
temperature
high temperature
Pump Warning
reduction by
Pump Warning
master
Page - 80/86
Description
Pump chopper current sensor
feedback too low (below 0,5V)
Problem on the EN-EVS
Shortcircuit on On/off coils
One or more on/off valve drivers
shorted (always ON)
One or more on/off valve drivers
opened (not able to close, so not
able to drive the valve)
Evp driver open (not able to close,
so not able to drive the valve)
Pump chopper current sensor
feedback too high (above 0,8V)
Pump current feedback is always
0A even when pump motor is
running
Pump motor temperature high
Slave is waiting the master
Wrong sequence in hydraulic
function request
Hydraulic poti (lift/lowering poti)
higher than minimum value
recorded, in stby condition
checksum ram failed
checksum eeprom failed
lift+lower request
eeprom is not online, or the
parameters in triplicate are different
When the parameter SET
TEMPERATURE is setted, the
temperature of the motor is >150°c
When the parameter maximum
current is 100% the current is
reduced lineary from 85°c to 105°C
Master requests a reduction
Machine status
Effect
when the test is
Pump motor stopped
stby
On/off valves stopped
start-up
On/off valves stopped
start-up, stby,
during valve
function
On/off valves stopped
start-up, stby
On/off valves stopped
during valve
function
Evp stopped
during Evp
function
Pump motor stopped
start-up, stby
Pump motor stopped
pump function
Pump chopper
continuous
maximum current
reduced to half
pump/valve stopped
continuous
pump/Evp stopped
start-up, stby
continuous
init
Pump motor stopped
continuous
Maximum current is
continuous
halfed
Pump chopper
continuous
maximum current
reduced proportionally
to T increase
pump speed reduced
continuous
AEQZP0BA – COMBI AC1 - User Manual
Restart
procedure
done
pump request
valve on/off request
valve on/off request
valve on/off request
valve on/off request
valve evp request
pump request
pump request
to do a correct
sequence
hydraulic request
hydraulic request
Need help?
Do you have a question about the COMBI AC1 and is the answer not in the manual?
Questions and answers