Menvier Security TS2000 User Manual page 40

(v2+) intruder alarm
Table of Contents

Advertisement

5.15
Define Outputs (Menu 16)
STEP ACTION
1
NO**
2
YES
3
YES
4
YES
5
NO
6
YES
7
000
8
YES
** from last step of previous menu
*
or Node
5.16
Review Wards (Menu 17)
STEP ACTION
1
NO*
2
YES
3
YES
4
000
5
YES
* from last step of previous menu
Issue 02 Feb 92
DISPLAY
Press <YES> to
DEFINE OUTPUTS
Press <YES> to
ALTER PANEL OUTPUTS
O/P >001 (Panel)* is
(Output Type)
O/P >002 (Panel)* is
(Output Type)
O/P 002 (Panel)* is
> (Output Type)
O/P >002 (Panel)* is
(new Output Type)
O/P >000 invalid No
YES to continue
Press YES to
DEFINE OUTPUTS
DISPLAY
Press <YES> to
REVIEW WARDS
CCT >001 in Ward(s)
* * * * * * * *
CCT >002 in Ward(s)
* 2 * * * * * *
CCT >000 NOT VALID
YES to continue
Press YES to
REVIEW WARDS
REMARKS
Press YES to Define Outputs. Press NO to go to Review Wards
menu. Use arrow keys to step through menus. Press 0 to quit
Press YES to alter PANEL outputs. Press NO to alter NODE outputs
then YES to continue
Press YES to accept displayed Panel or Node output configuration
and go to next output. Press NO to change it. Use arrow keys to step
through output number. Enter figures to select new output number
O/P 001 displayed configuration accepted. Press YES to accept
displayed output number. Press NO to change it. Use figures or
arrows to change output number
Output to be changed. Press NO to change and YES to accept. Use
arrow keys to step through output types
New configuration accepted. Continue steps 3 to 6 until all outputs
are defined then enter 000 to continue
Press YES or NO to return to step 1
Press NO to go to Review Wards menu. Press YES to repeat this
menu. Use arrow keys ro step through menus. Press 0 to quit
REMARKS
Press YES to Review Wards. Press NO to go to Define Ward Alarms
menu. Use arrow keys tostep through menus. Press 0 to quit
Press YES to accept displayed information and go to next circuit.
Press NO to return to step 1. Use arrow keys to step through cicuits.
Enter figures to select Circuits. Press 000 then YES to reurn to step 1
Information accepted. Circuit 2 is in ward 2. Continue as in step 2
Press YES/NO to go to step 1
Press NO to go to Define Ward Alarms menu. Press YES to repeat
this menu. Use arrow keys to step through menus. Press 0 to quit
TS2000 (V2+) User Manual