3
SYSTEM MENUS
3.1
Introduction
A series of Menus are provided which determine all the actions that may be taken to
programme or control the system. There are two entry points to the Menus, depending upon
whether an Engineer or a User passcode is entered, and the Menus may be stepped through
sequentially using the keyboard up and down arrow keys or accessed directly by entering the
Menu number for Menu items 1 to 9 (Fig 3 - 1).
3.2

Setting the System

3.2.1
The System may be Set after entering a passcode and the process is a two stage sequence
as follows:
(1)
Select the type of operation - what is to be set or omitted ;
(2)
Activate the Exit procedure.
3.2.2
The setting sequence at a REM is:
(1)
Omit circuits: Circuits that have been allocated the attribute Omit may be omitted by
passcodes Master and Manager and will not be set. They will be enabled when they
are unset unless unset by a key;
(2)
Set Wards: Wards may be selected and set by the designated passcode users as
well as or instead of the system - see below;
(3)
Set System: The system is Set using the programmed exit procedure;
3.2.3
There are three types of Exit procedure used when setting the System or a Ward that is fitted
with a WCU:
(1)
Timed Exit: the sequence is started and the System or Ward will set after a fixed
period, determined by the Exit Timer (para 3.8), by the end of which all monitored
circuits MUST be healthy to ensure Setting. The User may leave the protected
premises during this period without causing an alarm then after a further period,
determined by the Exit Settling Timer, the System or Ward will set ;
(2)
Exit by Circuit: The Exit sequence is started but the System or Ward (with WCU) will
only set by the momentary activation of a circuit which may be:
In each case final system setting is confirmed by the REM or WCU sounder being silenced.
3.3

Setting Wards

Wards may be selectively Set using a number of methods:
(1)
At a REM enter a passcode, designate the Wards to be set then command them to
set and they will set immediately with no further action required. This will be the
procedure where the REM is inside the area protected by the System and not the
Ward and no WCU is fitted;
(2)
Where the Ward has a REM inside it, its own exit and entry route, and a WCU is fitted,
then after entering a passcode at the REM the Exit procedure is activated in the same
way as for the System (para 4.2.3). The WCU sounder will indicate Ward setting is
complete;
(3)
Operation of a Ward Key, if one is fitted, will set the relevant Ward
Issue 02 Feb 92
(a)
The circuit designated Last Exit which starts the Exit Settling Timer; OR
(b)
The Last Exit followed by activation of the circuit designated Exit Terminator
which starts the Exit Settling Timer;
TS2000 (V2+) User Manual