Menvier Security TS2000 User Manual page 23

(v2+) intruder alarm
Table of Contents

Advertisement

4.2
Set System and all Available Wards (without WCU). Circuits may be Omitted
STEP ACTION
1
-
2
Enter passcode
3A
YES
3B
YES
4
YES
5A
-
5B
-
6
Last exit closed
7
-
* = Sounder on
Steps 3A & 3B occur only if Wards are defined
Step 4 occurs only if no Wards defined and circuits have attribute Omit
Steps 5 to 7 are the System Exit Sequence
4.3
Set System without Wards and with Circuits to be Omitted
STEP ACTION
1
-
2
Enter passcode
3
YES
4A
NO
4B
-
5
Last exit closed
6
-
Issue 02 Feb 92
DISPLAY
SYSTEM UNSET
(date) (time)
Press YES to
START SET SEQUENCE
SET?:- System (9) &
Ward 1 (to) 8
Ward set 1 (to) 8
Press YES to
OMIT/ENABLE CIRCUITS
*YOUR EXIT IS TIMED
xx mins yy secs left
(OR)
*LEAVE VIA EXIT ROUTE
All circuits healthy
*EXIT MODE COMPLETE
Attempting to set
SET SYSTEM 1 . . . . . 8
(date) (time)
DISPLAY
CIRCUITS OMITTED
(date) (time)
Press YES to
START SET SEQUENCE
OMITTED CIRCUITS
Press YES to view
*YOUR EXIT IS TIMED
xx mins yy secs left
(OR)
*LEAVE VIA EXIT ROUTE
All circuits healthy
*EXIT MODE COMPLETE
Attempting to set
SET SYSTEM 1 . . . . 8
(date) (time)
REMARKS
System and all wards are unset
Press YES to continue to step 3A or to step 4 or to step 5A. Press 0 to
quit. (Press NO to go to other Menus)
Only displayed if Wards are defined and only Wards with circuits will be
displayed. Press YES to set system and displayed wards. Press NO to
Omit circuits and return - see para 5.12. Press 0 to return to step 2
Wards without WCU being set (if any) momentarily displayed. Continue
at step 5A or 5B
Only displayed if circuits have attribute omit and no wards are defined.
Press YES to omit circuits and return - go to para 5.12. Press NO to
continue
Timed exit. Leave via the exit route within the time shown
Leave via the Last Exit and use the Exit Terminator if required
Exit time complete, or Last Exit used, or Last Exit used and Exit
Terminator operated. Delay for Exit Settling time
System and applicable wards all set ONLY when the sounder stops
REMARKS
System and all wards are unset. Circuits have been selected to be
omitted
Press YES to continue. Press 0 to quit. (Press NO to go to other
Menus)
Press NO to continue. Press YES to view omitted circuits then go to
Omit/Enable menu - para 5.6. Press 0 to go to Omit/Enable menu -
Para 5.6
Timed exit. Leave via the exit route within the time shown
Leave via the Last Exit and use the Exit Terminator if required
Exit time complete, or Last Exit used, or Last Exit used and Exit
Terminator operated.
Delay for Exit Settling time
System and applicable wards all set ONLY when the sounder stops
TS2000 (V2+) User Manual
Page 4-2