4.13
Clearing Circuits Omitted
STEP ACTION
1
-
2
Enter passcode
3
7
4
YES
5
YES
4.14
Set or Unset Wards Using Keys
STEP ACTION
1
-
2
Operate Ward Key
(latch or moment)
3
Operate Ward key
(latch or moment
Notes: (1) If the system is unset then all Wards will also be unset irrespective of the Ward Key positions;
(2) Unsetting a ward from a REM will override a Ward Key;
4.15
Unsetting the System
STEP ACTION
1
-
2A
Enter via
last exit
2B
(delay)
4
Enter Passcode
4.16
Unsetting the System (Alarm Present)
STEP ACTION
1
-
2
Enter via last
exit
3
Enter Passcode
4
Enter Passcode
5
0
* = Sounder on
Issue 02 Feb 92
DISPLAY
CIRCUITS OMITTED
(date) (time)
Press YES to
START SET SEQUENCE
Press YES to
OMIT/ENABLE CIRCUITS
CCT >XXX Armed
Type or Test
SYSTEM UNSET
(date) (time)
DISPLAY
SYSTEM UNSET
(date) (time)
SET-
1 (to) 8
(date)
(time)
SYSTEM UNSET
(date) (time)
DISPLAY
SET SYSTEM . . . . . . . .
(date)
(time)
*ENTER YOUR PASSCODE
xxx min xx sec left
*ENTER YOUR PASSCODE
xxx min xx sec left
SYSTEM UNSET
(date) (time)
DISPLAY
SET- SYSTEM . . . . . . .
(date) (time)
*ENTER YOUR PASSCODE
xxx min xx sec left
*CCT XXX (FULL ALARM)
(time) (date)
Press YES to
START SET SEQUENCE
SYSTEM UNSET
(date) (time)
REMARKS
Circuit or circuits have been omitted and action is required
Enter 7 to Omit or enable circuits. (Press Yes to view circuits and go
to set sequence -Para 5.2)
Press YES to change omitted circuits. (Press NO/0 to go to other
Modes)
First step of Omit sequence. Follow para 5.6 steps 1 to 7
All omitted circuits have been re-instated
REMARKS
System and all Wards are unset
Ward indicated is set
System and all Wards are unset
REMARKS
System is set and guarding the premises
Go immediately to the panel and enter your passcode within the
time specified
First entry time was exceeded. Fault sounder on and second time
displayed. Enter passcode within the time specified
System is unset and no longer guarding the premises
REMARKS
System is set and guarding the premises
Go immediately to the panel and enter your passcode within the time
specified
Alarm or fault occurred in circuit indicated at time shown. Enter
passcode to silence sounder
System is unset and no longer guarding the premises. Press YES to
set the system. Press 0 to quit. Press NO to go to other menus
System is unset and no longer guarding the premises