TS2000 (V2+) INTRUDER ALARM
CONTROL SYSTEM
USER MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Menvier Security TS2000

  • Page 1 TS2000 (V2+) INTRUDER ALARM CONTROL SYSTEM USER MANUAL...
  • Page 2 New Company Name This document is for use with the TS2000 Intruder Alarm Control system fitted with software versions 2.0 and above (V2+) issued after October 1991. It should not be used with earlier versions of the TS2000 system. It provides information on the Operation of the system.
  • Page 3: Table Of Contents

    TS2000 (V2+) User Manual CONTENTS OVERVIEW Introduction Page 1-1 Equipment Page 1-1 Control Panel Options Page 1-1 Additional Equipments Page 1-2 Remote Data Transfer Page 1-2 Fig 1-1 Schematic Block Diagram Page 1-3 OPERATIONAL FACILITIES Introduction Page 2-1 Control Page 2-1...
  • Page 4 TS2000 (V2+) User Manual OPERATING THE SYSTEM Introduction Page 4-1 Set System & all AvailableWards (w/o WCU) Page 4-2 Set System without Wards Page 4-2 Set System/Wards (w/o WCU) Cts Omitted Page 4-3 Set Wards Circuits Omitted Page 4-3 Set System/Wards (Wards set)
  • Page 5: Overview

    INTRUDER ALARM CONTROL SYSTEM TS2000 (S/W V2+) OVERVIEW Introduction The Intruder Alarm Control System TS2000 is provided for large domestic and general commercial intruder systems conforming to BS 4737 part 1 1986. It is an extremely versatile system with the following facilties: Will monitor up to 128 zones using various types of detector device;...
  • Page 6: Additional Equipments

    Unit but in large systems it may be necessary to fit additional power supply units. The PSU 150 has been designed for use with the TS2000 system and consists of a PSU and battery (supplied separately) and it may also have a Node Unit and a Relay Unit (para 1.4.6) fitted in its enclosure.
  • Page 7: Fig 1-1 Schematic Block Diagram

    No 32 (max) * = Option Distance between Nodes/Keypads must be less than 100m. Distance between Control Panel and last Node/Keypad must be less than 1km Fig 1 - 1 TS2000 Schematic Block Diagram Issue 02 Feb 92 Page 1 - 3...
  • Page 8: Operational Facilities Introduction

    TS2000 (V2+) User Manual OPERATIONAL FACILITIES Introduction 2.1.1 The system operates in two states which may be considered as 'Monitoring', when the system responds to circuit activations, and 'Operator Controlling' which requires the operator to enter a passcode and to operate a REM keypad.
  • Page 9: Circuit Types

    TS2000 (V2+) User Manual Master; Manager; Standard S (system); Standard W (ward); Restricted; Not Used; The highest level is (1) and the lowest is (6) so that the Engineer can carry out nearly all operations but the Manager can only carry out the operations allocated to passcode levels Manager, Standard and Restricted (Fig 3-1).
  • Page 10: Attributes

    TS2000 (V2+) User Manual When momentarily activated during Setting, after use of the Last Exit, will complete the Setting process if it has been programmed to do so (para 3.2); If activated momentarily during Timed Setting it will truncate the time and immediately complete the Setting process (para 3.2);...
  • Page 11 TS2000 (V2+) User Manual The System Activated Outputs may be allocated to any Node (NU or REM) output or the Panel (CP) outputs. They are designated by their function and may be programmed to be active if required. The following are available: Alarm: A system alarm is present (para 2.1);...
  • Page 12: Wards

    TS2000 (V2+) User Manual Exit: The relevant Ward (with WCU) exit procedure has been initiated (para 3.3); Entry: The relevant Ward (with WCU) entry procedure has been initiated (para 3.4); Ward outputs (1), (2), (3) and (6) above must be programmed and connected to the WCU if one is fitted.
  • Page 13: Modes

    TS2000 (V2+) User Manual Second Entry Time: Is an additional period of time allowed for entering protected premises that is activated after the First Entry Time has expired during which limited alarms will be activated. Default value is 30 seconds;...
  • Page 14: Omitting Circuits

    TS2000 (V2+) User Manual Re-arm: This may be set to Auto or to Manual. Auto Re-arm means that at the end of the Bell Duration period the circuit will repeat the alarm, if the alarm condition is still present, or if it re-occurs. Manual re-arming will inhibit the circuit, once it has generated an alarm, until the panel is reset.
  • Page 15: System Menus Introduction

    TS2000 (V2+) User Manual SYSTEM MENUS Introduction A series of Menus are provided which determine all the actions that may be taken to programme or control the system. There are two entry points to the Menus, depending upon whether an Engineer or a User passcode is entered, and the Menus may be stepped through sequentially using the keyboard up and down arrow keys or accessed directly by entering the Menu number for Menu items 1 to 9 (Fig 3 - 1).
  • Page 16: Unsetting The System

    TS2000 (V2+) User Manual Unsetting the System 3.4.1 The System may be unset in a number of ways: Entry Procedure: This is normally initiated by using the access designated as the Last Exit. This action starts the Entry Timer (para 2.8) and the Sounder will pulse at an increasing rate.
  • Page 17: Use Chime Facility

    TS2000 (V2+) User Manual The omitted circuits will be automatically enabled when the system or relevant ward is unset unless the ward is key controlled. 3.11 Use Chime Facility (Menu 8) Night circuits can be programmed to Chime when activated and the panel is Unset and this is done by: Selecting the circuits which are to chime when active;...
  • Page 18: Alter Time Lock

    TS2000 (V2+) User Manual used to enable Panel or Node outputs (para 2.6) at the times set and there is a manual override facility. 3.17 Alter Time Lock (Menu 14) The Time Lock is used to restrict Setting and Unsetting of the System or Ward 1 to certain times so that they must be Set before a certain time and may not be Unset until after a certain time.
  • Page 19: Define Panel Modes

    TS2000 (V2+) User Manual (11) Double Knock time: time period of double knock window; (12) Line Fault d: delay before line fault alarm. 3.23 Define Panel Modes (Menu 20) The system Modes of operation (para 2.9) that are required are selected and allocated: Select Exit: by Time, by Last Exit or by Last Exit and Exit Terminator;...
  • Page 20: Define Circuit Text

    TS2000 (V2+) User Manual this will be indicated by changing the end of line links at the old end unit and the new unit, also the system will not need to re-number all units, circuits and outputs. Having installed a unit the circuits and outputs will need to be programmed;...
  • Page 21: Reset By Remote

    TS2000 (V2+) User Manual Menu No Menu Level Ref Para Start Set Sequence 1, 2, 3, 4, 5, 6 432; 433 User Unset Wards 1, 2, 3, 4, 5, 6 View Circuits 1, 2, 3, 4, 5, 6 View Event Log...
  • Page 22 TS2000 (V2+) User Manual OPERATING THE SYSTEM Introduction 4.1.1 The system is controlled from a REM by using the keypad to control Menus. It is convenient to consider the Menus as three groups: Menus 1 and 2: Used by the Engineer and the Users to set the System and to set and unset Wards;...
  • Page 23 TS2000 (V2+) User Manual Set System and all Available Wards (without WCU). Circuits may be Omitted STEP ACTION DISPLAY REMARKS SYSTEM UNSET System and all wards are unset (date) (time) Enter passcode Press YES to Press YES to continue to step 3A or to step 4 or to step 5A. Press 0 to START SET SEQUENCE quit.
  • Page 24 TS2000 (V2+) User Manual Set System and Some or No Wards (without WCU). Circuits may be Omitted STEP ACTION DISPLAY REMARKS SYSTEM UNSET System and all Wards are unset (date) (time) Enter passcode Press YES to Press YES to continue. Press 0 to quit. (Press NO to go to other...
  • Page 25 TS2000 (V2+) User Manual Set System and Some or No Wards with Wards Previously Set (no WCU) and No Circuits Omitted STEP ACTION DISPLAY REMARKS SET - 1 (to) 8 Only the Wards indicated are set. Enter passcode for access...
  • Page 26 TS2000 (V2+) User Manual Set More Wards with Wards Previously Set (no WCU) and With Circuits Omitted STEP ACTION DISPLAY REMARKS SET - 1 (to) 8 Only the Wards indicated are set. Enter passcode for access (date) (time) Enter passcode Press YES to Press YES to continue.
  • Page 27 TS2000 (V2+) User Manual 4.11 Unset Wards with Circuits Omitted STEP ACTION DISPLAY REMARKS SET- 1 (to) 8 System has only the Wards indicated set. Enter passcode for access (date) (time) Enter passcode Press YES to Press NO to unset wards. Press 0 to quit. (Press YES to set - see para START SET SEQUENCE 4.2)
  • Page 28 TS2000 (V2+) User Manual 4.13 Clearing Circuits Omitted STEP ACTION DISPLAY REMARKS CIRCUITS OMITTED Circuit or circuits have been omitted and action is required (date) (time) Enter passcode Press YES to Enter 7 to Omit or enable circuits. (Press Yes to view circuits and go START SET SEQUENCE to set sequence -Para 5.2)
  • Page 29 TS2000 (V2+) User Manual PROGRAMMING THE SYSTEM Introduction 5.1.1 The system is initially programmed by an Engineer during commissioning but changes to programmed data may also be made by the Users. Programming may also be done using the Remote Data Transfer Facility. All the programming Menus are listed here in a step by step sequence (see Fig 3 - 1).
  • Page 30 TS2000 (V2+) User Manual View Circuits (Menu 3) STEP ACTION DISPLAY REMARKS Press <YES> to Press YES to View Circuits. Press NO to go to Event Log menu. Use VIEW CIRCUITS arrow keys to step through menus. Press 0 to quit CCT >001 Healthy...
  • Page 31 TS2000 (V2+) User Manual Select Bell Test (Menu 6) STEP ACTION DISPLAY REMARKS Press <YES> to Press YES to carry out Bell Test. Press NO to go to Omit/Enable SELECT BELL TEST Circuits menu. Use arrow keys to step through menus. Press 0 to quit...
  • Page 32 TS2000 (V2+) User Manual Chime Facility (Menu 8) STEP ACTION DISPLAY REMARKS Press <YES> to Press YES to use Chime Facility. Press NO to go to use the Printer. USE CHIME FACILITY Use arrow keys to step through menus. Press 0 to quit Press YES to Press YES to alter circuits that chime.
  • Page 33 TS2000 (V2+) User Manual Use The Printer (Menu 9) STEP ACTION DISPLAY REMARKS Press <YES> to Press YES to use the Printer. Press NO to go to Alter Clock menu. Use USE THE PRINTER arrow keys to step through menus. Press 0 to quit Press YES to Press YES to print everything except the Event Log and the Dictionary.
  • Page 34 TS2000 (V2+) User Manual Alter Clock (Menu 10) STEP ACTION DISPLAY REMARKS Press <YES> to Press YES to set system date and time. Press NO to go to Alter ALTER CLOCK Passcode menu. Use arrow keys to step through menus. Press 0 to quit Date is >DD/MM/YYYY...
  • Page 35 TS2000 (V2+) User Manual 5.11 Define Users (Menu 12) STEP ACTION DISPLAY REMARKS Press <YES> to Press YES to Define Users. Press NO to go to Alter Time Switch DEFINE USERS menu. Use arrow keys to step through menus. Press 0 to quit Press YES to Press YES to alter User type.
  • Page 36 TS2000 (V2+) User Manual 5.11 Define Users (Menu 12) (continued) STEP ACTION DISPLAY REMARKS (1234) Code confirmed OK Press any key Press any key ALTER PASSCODE Enter figures or use arrow keys to change User number. Continue Enter User No >02 steps10 to 13 for other Users if required.
  • Page 37 TS2000 (V2+) User Manual 5.12 Alter Time Switch (Menu 13) STEP ACTION DISPLAY REMARKS Press <YES> to Press YES to alter Time Switch. Press NO to go to Alter Time Lock ALTER TIME SWITCH menu. Use arrow keys to step through menus. Press 0 to quit ALTER TIME SWITCH Press YES to retain this time switch function.
  • Page 38 TS2000 (V2+) User Manual 5.13 Alter Time Lock (Menu 14) STEP ACTION DISPLAY REMARKS Press <YES> to Press YES to alter Time Lock. Press NO to go to Define Circuits ALTER TIME LOCK menu. Use arrow keys to step through menus. Press 0 to quit ALTER TIME LOCK Press YES to retain this Time function.
  • Page 39 TS2000 (V2+) User Manual 5.14 Define Circuits (Menu 15) STEP ACTION DISPLAY REMARKS Eng Passcode* Press <YES> to Press YES to Define Circuits. Press NO to go to Define Outputs menu. DEFINE CIRCUITS Use arrow keys to step through menus. Press 0 to quit 001<...
  • Page 40 TS2000 (V2+) User Manual 5.15 Define Outputs (Menu 16) STEP ACTION DISPLAY REMARKS NO** Press <YES> to Press YES to Define Outputs. Press NO to go to Review Wards DEFINE OUTPUTS menu. Use arrow keys to step through menus. Press 0 to quit Press <YES>...
  • Page 41 TS2000 (V2+) User Manual 5.17 Define Ward Alarms (Menu 18) STEP ACTION DISPLAY REMARKS Press <YES> to Press YES to define Ward Alarms. Press NO to go to Define Timers DEFINE WARD ALARMS menu. Use arrow keys to step through menus. Press 0 to quit Ward 1 alarm is Press YES to accept displayed information and go to next ward.
  • Page 42 TS2000 (V2+) User Manual 5.19 Define Panel Modes (Menu 20) STEP ACTION DISPLAY REMARKS Press <YES> to Press YES to Define Panel Modes. Press NO to go to Test Facilities DEFINE PANEL MODES menu. Use arrow keys to step through menus. Press 0 to quit...
  • Page 43 TS2000 (V2+) User Manual 5.20 Use Test Options (Menu 21) STEP ACTION DISPLAY REMARKS Press <YES> to Press YES to use Test Facilites menu. Press NO to go to Network USE TEST OPTIONS Options menu. Use arrow keys to step through menus. Press 0 to...
  • Page 44 TS2000 (V2+) User Manual 5.20 Use Test Options (Menu 21) (continued) STEP ACTION DISPLAY REMARKS Press <YES> to Press YES to see Software and Dictionary version numbers. Press SEE VERSION NO to go to Alter Reset Calculation. Use arrow keys to step through menus.
  • Page 45 TS2000 (V2+) User Manual 5.22 Use Network Options (Menu 22) (continued) STEP ACTION DISPLAY REMARKS Press YES to Press NO to go to Delete Node. Press YES to go to step 10. Press 0 to INSERT NEW NODE go to step 1 Press YES to Press YES to delete a Node.
  • Page 46 TS2000 (V2+) User Manual 5.24 Install DC3 (Digicom) (Menu 24) STEP ACTION DISPLAY REMARKS Press <YES> to Press YES to program Digital Communicator. Press NO to go to Start INSTALL DC3 Set Sequence menu. Use arrow keys to step through menus. Press 0...
  • Page 47 TS2000 (V2+) User Manual Issue 02 Feb 92 Page 5 - 19...
  • Page 48 TS2000 (V2+) User Manual 5.24 Install DC3 (Modem) (Menu 24 continued) STEP ACTION DISPLAY REMARKS PLEASE WAIT Loading Modem data MODEM NO Old number displayed. Enter figures of required number. Press NO 000000000000000000** to clear all numbers Press YES to accept displayed number...

Table of Contents