Menvier Security TS2000 User Manual page 11

(v2+) intruder alarm
Table of Contents

Advertisement

The System Activated Outputs may be allocated to any Node (NU or REM) output or the
Panel (CP) outputs. They are designated by their function and may be programmed to be
active if required. The following are available:
(1)
Alarm: A system alarm is present (para 2.1);
(2)
P.A.: A Personal Attack circuit or a Duress Alarm has been activated (para 2.4);
(3)
Set: The system is set (para 3.1.2);
(4)
Fire: A Fire circuit has been activated (para 2.4.1);
(5)
Medical: A Medical circuit has been activated (para 2.4.1);
(6)
Tamper: A Tamper alarm is present (para 2.4.1);
(7)
Aux: An Auxiliary circuit has been activated (para 2.4.1);
(8)
Set Fail: An attempt to set the system has failred (para 3.2);
(9)
Site Engr: The Engineer's passcode has been entered. The output will remain active
until a User passcode is entered (para 2.3.1);
(10)
Lock-Alarm: The system has not been set before the start of the Time Lock period
Para 3.17);
(11)
Test-Fail: A test failure has occurred (para 3.24);
(12)
AC Alarm: The mains supply to the PSU has not been present for the mains fail time
period Para 2.11);
(13)
AC Off: The mains supply to the PSU is not present or there is no 12V output (para
2.11);
(14)
Batt Fault: During the PSU test or while the mains is off the PSU battery voltage is low
(para 3.11);
(15)
Bell: The CP bell output (Relay) is activated (bells ringing);
(16)
Strobe: The CP Strobe output is activated (strobes on);
(17)
Switch+12: The system is Set and is not in alarm;
(18)
Walk Test +: A Walk Test is in progress (para 3.8);
(19)
Walk Test -: A Walk Test is in progress (para 3.8);
(20)
Line Fault: A Digicom telephone line fault is present (para 1.3.1);
(21)
Time Switch: The programmed Time Switch (para 3.16) is active;
(22)
Time Locked: The system has been Timed Locked (para 3.17) and cannot be unset;
(23)
Entry Mode: Entry mode has been initiated (para 3.4);
(24)
2nd Entry: The first Entry Time has timed out before a passcode entry (para 3.4);
(25)
Exit Mode: System exit procedure has been initiated (para 3.2);
(26)
Exit Setting; Final Exit setting is in progress (para 3.2) ;
(27)
Exit Error: An error occurred during the exit procedure and the system cannot set
(para 3.2);
(28)
Lock Alert: The programmed Time Lock period is about to start (para 3.17);
(29)
Fire/Viper: Used to supply devices which latch when activated and which are
unlatched when power is removed. The output is removed for about three seconds
when unsetting the system after an alarm at the second passcode entry;
(30)
PSU Test: Connected to remote PSU to initiate a battery test (para 2.11).
CAUTION: It is essential to ensure that the correct outputs that will source (supply) or sink (accept)
current are selected to match the function required.
2.6.4
The Ward activated outputs may be programmed to be active if required and the following are
available:
(1)
Set: The relevant ward has been set (para 3.3);
(2)
Set Fail: An attempt to set the relevant ward failed (para 3.3);
(3)
Alarm: The relevant ward is active or in alarm;
(4)
Walk Test +ve: The relevant ward is in Walk Test (para 3.8);
(5)
Walk Test -ve: The relevant ward is in Walk Test (para 3.8);
Issue 02 Feb 92
TS2000 (V2+) User Manual