4.6
Set System and Some or No Wards with Wards Previously Set (no WCU) and No Circuits Omitted
STEP ACTION
1
-
2
Enter passcode
3A
YES
3B
YES
4
YES
5
Leave
4.7
Set System and Some or No Wards with Wards Previously Set (no WCU) and Circuits Omitted
STEP ACTION
1
-
2
Enter passcode
3
YES
4
NO (or view)
5
YES
(OR)
6
YES
4.8
Set More Wards with Wards Previously Set (no WCU) and No Circuits Omitted
STEP ACTION
1
-
2
Enter passcode
3
YES
4
9 1 (to) 8
5
YES
6
-
Issue 02 Feb 92
DISPLAY
SET -
1 (to) 8
(date) (time)
Press YES to
START SET SEQUENCE
SET? :- SYSTEM (9) &
Ward 1 (to) 8
(or step 4)
WARDS SET 1 (to) 8
Press YES to
OMIT/ENABLE CIRCUITS
(Exit sequence)
DISPLAY
SET-
1 (to) 8
(date) (time)
Press YES to
START SET SEQUENCE
OMITTED CIRCUITS
Press YES to view
SET? :- SYSTEM (9) &
Ward 1 (to) 8 (or Ward . . . . )
WARDS SET 1 (to) 8
(Exit sequence)
DISPLAY
SET
1 (to) 8
date time
Press YES to
START SET SEQUENCE
SET? :- SYSTEM (9) &
Ward 1 (to) 8
(or step 4)
SET? :- Only
Wards 1 (to) 8
WARDS SET 1 (to) 8
SET-
1 (to) 8
(date) (time)
REMARKS
Only the Wards indicated are set. Enter passcode for access
Press YES to continue then go to step 3A or 4. Press 0 to quit. (Press
NO to Unset wards)
Only if some wards are not set. Enter numbers of Wards not to be set -
figures will 'toggle'. Press YES to set system and displayed wards.
Press NO to omit circuits and return - see Para 5.6. Press 0 to return to
step 2
Wards being set, if any, momentarily displayed then go to step 5
There are no wards to be set. Press YES to omit circuits and continue -
see Para 5.6. Press NO/0 to set system only and exit
See Para 4.2 steps 5 to 7
REMARKS
Only the Wards indicated are set. Enter passcode for access
Press YES to continue. Press 0 to quit. (Press NO to Unset wards)
Circuits have been omitted. Press YES to view them and then to
continue. Press NO/0 to continue
Wards not set shown. Enter numbers of Wards not to be set - figures
will 'toggle'. Press NO to omit circuits and return - see Para 5.6. Press
YES to set system & displayed wards. Press 0 to return to step 2
Wards being set momentarily displayed - only if wards are to be set
See Para 4.2 steps 5 to 7
REMARKS
Only the Wards indicated are set. Enter passcode for access
Press YES to continue. Press 0 to quit. (Press NO to Unset wards)
Wards not set shown. Enter 9 to delete system and numbers 1 to 8 of
Wards not to be set - figures will toggle'. Press NO to omit circuits and
return - see Para 5.6. Press 0 to return to step 2
System deleted. Only Wards not deleted will be displayed. Press YES
to set these wards. Press NO to omit circuits and return - see Para 5.6.
Press 0 to return to step 2
Wards being set, if any, momentarily displayed
Only the wards indicated are set