Download Print this page

Kenmore 66475272502 Installation Instructions Manual page 8

30" (76 cm) freestanding gas range with triple task oven drawer

Advertisement

5,
To mount anti-tip bracket to wood floor, drill two 1/8"(3.2 mm)
holes at the positions marked on the bracket template.
Remove template from floor.
Place rack in oven. Place level on rack, first side to side; then
front to back.
6,
7.
8,
9.
To mount anti-tip bracket to concrete or ceramic floor, use a
3_6" (4.8 mm) masonry drill bit to drill 2 holes at the positions
marked on the bracket template. Remove template from floor.
Tap plastic anchors into holes with a hammer.
Align anti-tip bracket holes with holes in floor. Fasten anti-tip
bracket with screws provided.
Depending on the thickness of your flooring, longer screws
may be necessary to anchor the bracket to the subfloor.
Longer screws are available from your local hardware store.
Move range close to opening. Remove shipping base,
cardboard or hardboard from under range.
Move range into final position making sure rear leveling leg
slides into anti-tip bracket.
If range is not level, pull range forward until rear leveling leg is
removed from the anti-tip bracket. Use channel lock pliers to
adjust leveling legs up or down until range is level. Push range
back into position. Check that rear leveling leg is engaged in anti-
tip bracket.
NOTE: Oven must be level for satisfactory
baking performance.
Typical
rigid pipe connection
A combination
of pipe fittings must be used to connect the range
to the existing gas line. Your connections
may be different,
according to the supply line type, size and location.
1. Apply pipe-joint
compound
made for use with LP gas to all
pipe thread connections.
2. Using a pipe wrench to tighten, connect the gas supply to the
range.
F
10. If installing the range in a mobile home, you must secure the
range to the floor. Any method of securing the range is
adequate as long as it conforms to the standards in the
"Location Requirements"
section.
11. Continue installing your range using the following installation
instructions.
/
H
G
A. Gas pressure regulator
B. 90 ° elbow (must have
_/2"male pipe thread)
C. Nipple
D. Union
E. Black iron pipe
F. Manual gas shutoff valve
G. _2" or 3/4"gas pipe
H. Nipple
I. Union
J. 90 ° elbow
Typical flexible
connection
1. Apply pipe-joint
compound
made for use with LP gas to the
smaller thread ends of the flexible connector adapters (see B
and G in following illustration).
2. Attach one adapter to the gas pressure regulator and the
other adapter to the gas shutoff valve. Tighten both adapters.