GAS CONVERSIONS
Explosion
Hazard
Use a new CSA Internationam approved
gas supply
line.
Install a shut-off
valve°
Securemy tighten
aH gas connections.
tf connected
to LP, have a qualified
person make sure
gas pressure does not exceed 14" (36 cm) water
comumn.
E×ampmee of a qualified
person incmude:
licensed heating
personnel,
authorized
gas company
personnel, and
authorized
service
personnel°
Failure to do so can result in death, explosion,
or fire.
2. Remove Triple Task Oven Drawer. Remove the access panel
at the center rear of the compartment.
Locate gas pressure
regulator at the back of the range.
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.
Gas pressure
regulator
3. Remove plastic cover from gas pressure regulator cap.
4. Turn gas pressure regulator cap counterclockwise
with a
%" combination
wrench to remove.
NOTE: Do not remove the spring beneath the cap.
Side view before
A
i[i :::;_
B
rip Over Hazard
A child or adumt can tip the range and be killed°
Connect anti-tip
bracket to rear range foot.
Reconnect
the anti=tip bracket,
if the range is moved.
Failure to fellow these instructions
can result in death
or serious burns to chimdren and adumts.
To Convert
Gas Pressure
Regulator
C
Side view after
A. Plastic cover
B. Gas pressure regulator cap with solid end facing out
C. Gas pressure regulator cap with hollow end facing out
D. Washer
E. Gas pressure regulator cap
5. Turn over the gas pressure regulator cap and reinstall on
regulator so that the hollow end faces out and the marking
"<- LP" is facing the direction shown in the above drawing.
6. Replace plastic cover over gas pressure regulator cap.
To Convert
Standard
Surface
Burners
1. Ensure that the manual shutoff valve is in the closed position
and the power supply cord is unplugged.
Using a Phillips or Quadrex screwdriver, remove the burner
base.
NOTE: Reinstall one of the screws through the range cooktop
to hold the orifice spud holder in place while removing and
replacing the orifice spuds.
A. To range
B. Manual shutoff valve "closed" position
C. Gas supply line