Electrical Interface Connection
1.
Using the cable diagram and parts list below, build an appropriate length UPS to 3D printer
cable;
2.
Connect the cable from the UPS unit's I/O Module (25-pin DSub) connector to the UPS (9-pin
DSub) connector on the rear of the 3D printer.
Note:
their respective mates (do not over-tighten)
3.
Follow the instructions in the UPS Installation and Operation Guide to set the "Low Battery
Warning Level" to 8 minutes.
Note:
the 3D printer can shut down safely.
Parts List – Cable, UPS to 3D Printer
Item
Qty
Nomenclature / Description
1
1
Conn, Hsg, Plug, 9PosS
2
1
Conn, Hsg, Plug, 25Pos
3
6
Pin, Male, 24-20 AWG
4
1
Shell, Size 1, 9-Pin w/Grommets
5
1
Shell, Size 3, 25-Pin w/Grommets
6
2
Jackscrew Pair 4-40, Knurled
7
1
XX (length needed)Cable, 2 Conductor, 22 AWG
8
1
4.5 inch (1 15 mm) Sleeving, Heatshrink 1/4 Inch (7 mm)
9
1
Conn, Hsg, Plug, 9Pos-Solder Cup
10
1
Conn, Hsg, Plug, 25 Pos-Solder Cup
References
1.
APCC Smart-UPS Installation and Operation Guide
2.
APCC Relay I/O Module User's Guide
Make certain to install the jackscrews that hold the cable connectors to
The default value of 2 minutes may not provide adequate time to ensure
Material Specification
AMP - 205204- 1
AMP - 205208- 1
AMP - 1-66506-0 or 66506-4
AMP - 748677- 1
AMP - 748677-3
AMP - 747784-3
ALPHA - 1 172C or Equivalent
3M - FP301 or Equivalent
AMP - 747904-4
AMP - 747912-4