Error issuing command. The driver does not recognize the target
device.
[xxxxx021]
Device protocol error. An unexpected event occurred during data
transfer between the adapter and target device. Normally, this
indicates a faulty or noncompliant target device.
[xxxxx022]
Adapter or target device protocol error. The adapter or target device
has broken the communication protocol. A badly behaving device
could be cause this message to appear. Normally this is not a serious
problem. If you get this message frequently over a short period of
time, it could indicate that the device or system is malfunctioning.
Unplug or power down unused devices to see if the problem
persists.
[xxxxx023]
Target device parity error. The driver has detected a parity error by
the target device.
[xxxxx024]
Data overrun or underrun. The adapter was given more or less data
than the expected amount of data.
[xxxxx031]
Target device queue full. The target device internal buffer is full.
[xxxxx032]
Target device busy. The target device reports a busy status. Another
program may already be using this device.
[xxxxx050]
[xxxxxx9A]
Host adapter failure. Your host adapter may not be properly
installed or is defective. Try re-seating the adapter in the PCI slot, or
try installing it a different PCI slot.