Refer to the nameplate on the front of the appliance.
Verify the ELECTRICAL SERVICE POWER.
Voltage and phase must match the nameplate specifications, and
available electrical service amperage must meet or exceed the
specifications listed on page 1.
Wiring must be no less than 4 AWG solid copper wire, rated for at
least 90ºC.
NOTE: Wire gauge, insulation type and temperature rating , as well as
type, size and construction of conduit, must meet or exceed applicable
specifications of local codes and of the National Electrical Code.
This appliance is equipped with a Hubble™ L430P9 plug, which must
be plugged into a matching Hubble™ L430R9 receptacle. The ground
lug of the receptacle must be connected to a suitable building ground.
IMPORTANT:
The appliance is shipped from the factory wired for 3-phase (3ø)
electrical service. This appliance is not approved for 1ø operation.
Conversion of this appliance to single-phase operation will void the
warranty
DANGER: ELECTRICAL SHOCK HAZARD
ELECTRICAL CONNECTIONS MUST BE MADE BY A
LICENSED ELECTRICIAN
Electrical shock will cause death or serious injury.
7
INSTALLATION (continued)
CAUTION:
Risk of
Damage
DO NOT connect or energize
this appliance until all
installation instructions are
read and followed. Damage
to the appliance will result if
these instructions are not
followed.
CAUTION:
Electrical Shock
Hazard
The ground lug of this
appliance must be connected
to a suitable building ground.
IMPORTANT:
Contact a licensed electrician
to install and connect
electrical power to the
appliance.
IMPORTANT:
Damage due to being
connected to the wrong
voltage or phase is NOT
covered by warranty.
.