Over-temperature Conditions

Routine Maintenance

XM Series Inverter Unit

Batteries

975-0263-01-01
Important:
If you are unsure about operating any device with the XM Series
Inverter, contact the manufacturer of the device.
When the XM Series Inverter senses its internal temperature approaching
its limit, the alarm beeps every two seconds and the display shows fault
code E07 alternating with "OtA".
If the over-temperature condition persists, the XM Series Inverter shuts
down to protect itself. The alarm beeps once per second and the display
shows fault code E08 alternating with "Ot".
Minimal maintenance is required to keep your XM Series Inverter
operating properly. Periodically you should:
Clean the exterior of the unit with a damp cloth to prevent the
accumulation of dust and dirt.
Ensure that the DC cables are secure and fasteners are tight.
Make sure the ventilation openings are not clogged.
When possible, you should recharge your batteries whenever a low
voltage shutdown occurs with the XM Series Inverter. This gives the
batteries a much longer life than recharging when the batteries have been
almost completely discharged. For more information on maintaining
batteries, see "Battery Tips" on page B–7.
For information about Xantrex battery chargers, see our web site at
www.xantrex.com.