About Charging; Charging Time - Xantrex Truecharge TC20+ Owner's Manual

Truecharge 20+/40+ amp multistage battery charger
Table of Contents

Advertisement

Operation

About Charging

This section provides information about

Charging Time

Formula
Charging time will depend on the capacity of your battery and on how
deeply it is discharged.The following equation calculates an approximate
charging time:
Charging time = CAP x DOD
where:
Charging Time:
CAP:
DOD:
CC:
80%:
Example
A Group 27 size battery rated at 82 amp-hours is 40% discharged, that is,
it has a DOD = 40. Charging time with a Truecharge 20+ unit is
calculated as follows:
Charging time = 82 Ah x 40% = 2 hours
3–2
calculating the charging time
effect of battery temperature on charging
indicator light activity during the charging process
using a generator to run Truecharge+
CC x 80%
Battery recharge time in hours
Battery capacity in amp-hours
Battery depth of discharge in per cent. A fully
discharged battery has 100% DOD
Charge current, the rated current output of the
charger in amperes
Typical charging efficiency for lead-acid batteries
20 A x 80%