G. Control Module Operation
1.
The control module has an ON/OFF/REMOTE selector
switch that must be set. See Figure 12.4.
OFF Position: Appliance will ignore all power
inputs and will not respond to any commands from
a wall switch or remote. The unit should be in the
OFF position during installation, service, battery
installation, fuel conversion, and in the event that
the control goes into LOCK-OUT mode as a result
of an error code.
ON Position: Appliance will ignite and run
continuously in the HI flame setting, with no
adjustment in fl ame output. This mode of operation
is primarily used for initial installation or power
outage operation with battery backup.
REMOTE Position: Appliance will initiate commands
from an optional wired wall switch and/or the wireless
remote (RC300).
2.
If using a wired wall switch with the module in
REMOTE mode, the fl ame output can be adjusted
with the HI/LO selector switch on the module. See
Figure 12.4. Note that the flame HI/LO selector
switch will become inactive once an optional remote
control (RC200/RC300) is programmed to the control
module. Note that the control module will always ignite
the fi replace on HI and remain so for the initial 10
seconds of operation. If the HI/LO is switched to the
LO position, the fl ame output will automatically drop to
the lowest setting after the fl ame has been established
for 10 sec. After this 10 second period, the fl ame can
be adjusted from HI to LO with the switch.
3.
The control module has safety feature that automatically
shuts down the fi replace after 9 hours of continuous
operation without receiving a command from the
RC300 remote.
4.
If you intend to use both an optional wired wall
switch and the RC300 remote control to operate your
fi replace, the wall switch will override any commands
given by the remote.
5.
The module has the capability to recognize potential
malfunctions. If these occur, it will fail to ignite and/or
respond to a command to ignite via the wall switch
and/or remote. In this case, the module may have
gone into LOCK-OUT mode. In this state, it will emit
a RED/GREEN LED error code. To reset the error
code, switch the selector to OFF, and then back to
REMOTE or ON. If the ignition command again fails,
the module will emit an LED error code, prior to going
back into LOCK-OUT mode. Contact your dealer for
service if this occurs.
Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. G • 12/09
STATUS INDICATOR LED
FLAME HI/LO SWITCH
Figure 12.4 Control Module