Table of Contents

Advertisement

Quick Links

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
NOTICE: DO NOT discard this manual!
Models:
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certified kit is used.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fitter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20
Installation Manual
Installation and Appliance Setup
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed
by a qualified installer, service agency, or the
gas supplier.
DANGER
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and must be installed for
the protection of children and other at-risk
individuals.
HOT GLASS WILL
CAUSE BURNS.
UNTIL COOLED.
TO TOUCH GLASS.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo 6000CMOD-IFT

  • Page 1 In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter. See Table of Contents for location of additional Commonwealth of Massachusetts requirements. Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 2: Table Of Contents

    D. Installing the Non-combustible Board....33  = Contains updated information. Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 3: Installation Standard Work Checklist

    _____________________________________________________________________________________ _________________________________________________________________________________________________ _________________________________________________________________________________________________ Comments Communicated to party responsible ____________________ by ______________________on ___________ (Builder / Gen. Contractor/) (Installer) (Date)  = Contains updated information. 2509-982D 6/20 Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 4: Product Specific And Important Safety Information

    State of California to cause cancer and reproductive harm. For more information go to: www. P65Warnings.ca.gov. Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 5: Requirements For The Commonwealth Of Massachusetts

    VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- of the installation. STRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 6: Getting Started

    1/2 - 3/4 in. length, #6 or #8 Self-drilling screws Caulking material (300 ºF minimum continuous exposure rating) One 1/4 in. female connection (for optional fan). Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 7: Inspect Appliance And Components

    Call a qualified service technician to inspect the appliance and to replace any part of the control system and/or gas control which has been under water. Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 8: Framing And Clearances

    Millimeters 1041 11-11/16 36-1/8 28-1/2 33-1/2 14-1/4 34-5/8 8-1/2 2-1/4 2-7/8 9-11/16 8-1/2 6 dia 39-7/8 1013 40-7/8 1038 14-3/16 15-3/8 Figure 3.1 Appliance Dimensions-6000 Models Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 9 Inches Millimeters 11-11/16 1219 35-1/2 43-1/8 1096 35-1/2 17-3/4 36-5/8 8-1/2 2-3/8 2-7/8 9-15/16 8-1/2 41-7/8 1064 42-7/8 1089 14-1/16 17-1/16 Figure 3.2 Appliance Dimensions-8000 Models Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 10 7-11/16 32-7/8 34-1/8 6000 ARC-36 39-7/16 22-7/16 44-1/4 1-1/4 7-11/16 34-13/16 36-1/16 8000 ARC-42 1002 1124 Figure 3.3 Decorative Front Dimensions - Folio and Arcadia  Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 11 7-7/8 32-7/8 34-1/8 6000 CHA-36 22-7/16 39-7/16 44-1/8 1-1/4 7-7/8 34-13/16 36-1/16 8000 CHA-42 1002 1121 Figure 3.4 Decorative Front Dimensions - Halston and Chateau  Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 12 1-1/4 7-1/2 32-7/8 34-1/16 6000 GALLERIA-6 38-9/16 22-3/4 44-1/16 1-1/4 7-1/2 34-3/4 8000 GALLERIA-8 1121 Figure 3.5 Decorative Front Dimensions - Chateau Forge and Galleria  Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 13 32-7/8 34-1/8 6000 FSI-36 34-3/8 25-3/16 44-3/16 1-1/4 6-3/4 34-13/16 36-1/16 8000 FSI-42 1122 Figure 3.6 Decorative Front Dimensions - Clean Face and Iron Age  Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 14: Clearances To Combustibles

    ONE 90º ELBOW 17-3/4 See Section 10.B 6000 Mantel Projections 1295 1067 1829 55-7/8 19-3/4 See Section 10.B 8000 Mantel Projections 1419 1245 2007 Figure 3.5 Appliance Locations Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 15 (Height) (Depth) (Width) 40-1/8 6000 1019 1067 42-1/8 8000 1070 1245 * Adjust framing dimensions for interior sheathing (such as sheetrock). Figure 3.6 Clearances to Combustibles Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 16: Constructing The Appliance Chase

    • The chase must be properly blocked to prevent blown insulation or other combustibles from entering and making contact with fireplace or chimney. • Failure to maintain airspace may cause overheating and a fire. Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 17: Termination Location And Vent Information

    Refer to local codes. H=Measure Horizontal Distances from H V=Measure Vertical Distances from V Figure 4.1 Minimum Height From Roof to Lowest Discharge Opening Figure 4.3 Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 18: Vent Terminal Clearances

    12 in. (305 mm)* two sides beneath the floor.) vinyl or composite overhang 42 in. (1067 mm) 42 in. (1067 mm) Figure 4.4 Minimum Clearances for Termination Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 19: Approved Pipe

    WARNING! Risk of Fire or Asphyxiation. This appli- ance requires a separate vent. DO NOT vent to a pipe serving a separate solid fuel burning appliance. Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 20: Use Of Elbows

    8-1/2 DVP24 DVP36 25-1/2 DVP48 1219 DVP6A 3 to 6 76 to 152 2-1/8-4-1/4 54-108 DVP12A 3 to 12 76 to 305 2-1/8-8-1/2 54-216 Figure 4.5 Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 21: Measuring Standards

    • Horizontal pipe installed level with no rise. MEASURE TO SHADED SURFACE (OUTSIDE MOUNTING SURFACE) Figure 4.7 Measure to Outside Mounting Surface Figure 4.8 Measure to Top of Last Section of Pipe Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 22: Vent Diagrams

    Failure to keep insulation or other material away released. See Figure 4.9. from vent pipe may cause fire. 1/4 in. max. (6 mm) Figure 4.9 Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 23 = 20 ft. (6.1 m) Maximum = 40 ft. (12.2 m) Maximum = 20 ft. (6.1 m) Maximum ELBOW HEAT SHIELD (Required when V = 2 ft. or less) Figure 4.10 Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 24 = 1 ft. (305 mm) Minimum = 40 ft. (12.2 m) Maximum = 20 ft. (6.0 m) Maximum = 1 ft. (305 mm) Minimum INSTALLED HORIZONTALLY Figure 4.11 Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 25 16 ft * 4.9 m* 3 ft. 914 mm 14 ft.* 4.3 m* = 20 ft. (6.1 m) Maximum = 40 ft. (12.2 m) Maximum Figure 4.12 Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 26 See Figure 4.16. Vertical 4 ft. 8 ft. 15 ft. 20 ft. 25 ft. 30 ft. 35 ft. Figure 4.13 40 ft. Figure 4.15 Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 27 1.2 m 20 ft. 6.1 m = 50 ft. (15.2 m) Maximum *No specific restrictions on this value EXCEPT cannot exceed 50 ft (15.2 m) Figure 4.17 Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 28 1.2 m 18 ft. 5.5 m 18 ft. 5.5 m = 20 ft. (6.1 m) Maximum = 40 ft. (12.2 m) Maximum INSTALLED HORIZONTALLY Figure 4.18 Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 29: Vent Clearances And Framing

    • SLP pipe - A wall shield firestop must be placed on each side of an interior wall. A minimum 1-1/2 in. (38 mm) overlap of attached heat shields must be maintained. Figure 5.2 Wall Penetration Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 30: Ceiling Firestop/Floor Penetration Framing

    INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 5.4 Installing the Attic Shield Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 31: Appliance Preparation

    3. Secure the first section of venting to the firebox by at- taching to the starting collar with screws. See Figure 6.4. Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 32: Installing Optional Heat Management Systems

    Reference the appropriate instructions included with the kit for the remaining installation steps. HEAT MANAGEMENT KNOCKOUT LOCATIONS (LEFT AND RIGHT SIDES) Figure 6.5 Heat Management Knockout Locations Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 33: Securing And Leveling The Appliance

    HEADER HEADER Figure 6.8 Non-combustible Board Note: Diagonal dimensions (A) and (B) must be within 1/4 inch of each other. Figure 6.6 Positioning the Appliance Squarely Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 34: Venting And Chimneys

    If predrilling holes, DO NOT penetrate inner pipe. INCORRECT Figure 7.4 Seams For 90º and 45º elbows that are changing the vent direction Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 35: Assemble Vent Sections (Slp Pipe)

    Use care when remov- ing termination cap from slip pipe. If slip section seals are broken during removal of the termination cap, vent could leak. Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 36: Assemble Slip Sections

    • Only outer pipes are sealed, sealing the inner flue is not required. • All unit collar, pipe, slip section, elbow and cap outer flues shall be sealed. Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 37: Secure The Vent Sections

    Figure 7.10 Rotate Seams for Disassembly connection point to appliance. 120º Figure 7.11 Align and Disassemble Vent Sections Figure 7.8 Securing Vertical Pipe Sections 120º Figure 7.9 Securing Horizontal Pipe Sections Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 38: Vertical Termination Requirements

    • Tighten nut and make sure the collar is tight against the Opening pipe section. • Caulk around the top of the storm collar. See Figure 7.15. Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 39: Horizontal Termination Requirements

    • Rest the small leg on the extended heat shield on top of the pipe section to properly space it from the pipe section. Figure 7.15 Figure 7.15 Important Notice: Heat shields may not be field constructed. Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 40 DVP-TRAP1 can adjust 1-1/2 in. (3-1/8 to 4-5/8 in.) DVP-TRAP2 can adjust 4 in. (5-3/8 to 9-3/8) DVP-HPC1 can adjust 2-1/8 in. (4-1/4 to 6-3/8) DVP-HPC2 can adjust 4-1/8 in. (6-3/8 to 10-1/2) Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 41: Electrical Information

    Verify proper operation after servicing. WARNING! Risk of Shock! Replace damaged wire with type 105º C rated wire. Wire must have high temperature insulation. Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 42: Wiring Requirements

    ELECTRONIC CONTROL MODULE RF MODULE (FOR USE WITH OPTIONAL REMOTE CONTROL) 6 PIN APPLIANCE 6V DC ON/OFF BATTERY PACK CONTROL Figure 8.2 IntelliFire Touch Wiring Diagram Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 43 Figure 8.3 Junction Box Wired to Wall Switch (1/4 in. male) as shown. Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 44: Gas Information

    Check with your local gas utility to determine proper • If substituting for these components, please consult orifice size. local codes for compliance. Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 45: Air Shutter Setting

    NOTICE: If sooting occurs, provide more air by opening the air shutter. Appearance of components may vary. AIR SHUTTER WING NUT Figure 9.1 Air Shutter Air Shutter Settings 6000CMOD-IFT Fully Closed 8000CMOD-IFT Fully Open Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 46: Finishing

    If desired finishing includes a painted wall, 100% acrylic Figure 10.1 Facing Materials latex with compatible primer is recommended around this appliance. Oil-based or standard acrylic paints may dis- color due to heat exposure. Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 47: Mantel And Wall Projections

    = 35-1/2 IN. (8000CMOD-IFT) Note: Measurement is taken from top of the opening, NOT the top of the fireplace. Figure 10.4 Minimum Vertical and Maximum Horizontal Dimensions - Non-Combustible Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 48: Decorative Fronts

    0-6 inches max. 10.8 Overlap 1 inch or less 10.6 Iron Age Inside 1-6 inches max. 10.7 Figure 10.6 Finishing Material 1 Inch Thick or Less Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 49 36-5/16 34-7/16 DECORATIVE FRONT (Outside decorative front width) (Includes 1/8 in. opening each side of decorative front) Figure 10.7 Finishing Material Thickness Greater Than One Inch Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 50 NON-COMBUSTIBLE FINISHING MATERIAL FINISHING STRIPS DECORATIVE FRONT FINISHING MATERIAL FINISHING MATERIAL Figure 10.8 Inside Fit (Folio/CF) FINISHING STRIPS REMOVED Figure 10.9 Removing Finishing Strips. Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 51: Appliance Setup

    Clean/vacuum any sawdust that may have accumulated inside the firebox or underneath in the control cavity. LATCHES (BOTH BOTTOM AND TOP) GLASS ASSEMBLY Figure 11.1 Fixed Glass Assembly Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 52: Glass Panel Installation

    Figure 11.5 Install Side Retainers BACK REFRACTORY BACK REFRACTORY BRACKET INSTALLED BRACKET INSTALLED SIDE SIDE PANEL PANEL REAR REAR PANEL PANEL Figure 11.3 Side Panel Flush with Rear Panel Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 53: Media Placement

    PILOT OPENING (WHITE AREA) Figure 11.8 Placement of Media BURNER NO MEDIA ON PILOT OPENING (WHITE AREA) Figure 11.6 Rock Fixture Installed Figure 11.9 Placement of Media Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 54: Intellifire Touch ® Control System Setup

    1. The RC400 remote will need to be paired to the ECM. 2. Follow the installation instructions provided with the IntelliFire Touch remote and/or accessory kit(s). Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 55: Reference Materials

    6 in. (152 mm) 14 IN. (356 MM) 12 IN. (305 MM) DVP-WS (Wall Shield Firestop) DVP-RDS ROOF DECK INSULATION SHIELD Figure 12.1 DVP Vent Components Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 56 117 mm Length DVP-TRAP 5-3/8 in. 9-3/8 in. Trap2 Horizontal Termination Cap 137 mm 238 mm DVP-TRAP2 DVP-TRAP1 DVP-TRAPK2 DVP-TRAPK1 DVP-HPC1 DVP-HPC2 Figure 12.2 DVP Vent Components Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 57 9-1/2 in. (352 mm) (241 mm) 26 in. 660 mm 14 in. (356 mm) DVP-HSM-B DRC-RADIUS Extended Heat Shield Cap Shield Figure 12.3 DVP Vent Components Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 58 7-3/4 to 10-3/8 in. (222 mm) (197 to 264 mm) DVP-FBHT 1-5/8 in. FireBrickTermination Cap (41 mm) DVP-HPC High Performance Cap Figure 12.4 DVP Vent Components Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 59 Only use listed decorative termination caps/shrouds with Hearth & Home Technologies approved venting systems. This applies to both DVP and SLP venting systems. Decorative Terminations Caps/Shrouds DTO134 DTO146 DTS134 DTS146 LDS33 LDS46 LDS-BV Figure 12.5 DVP Vent Components Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 60 Option A: IFT-RC400 Option B: IFT-RC150 and IFT-ACM. These accessories are purchased separately from the PVV-SLP. Contact your dealer to order. Figure 12.6 PVV-SLP Vent Components Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 61 (346 mm) 424 mm (424 mm) 12-1/2 IN. (318 mm) SLP-LPC SLP Low Profile Cap (Approved for use with PVI-SLP-B only) Figure 12.6 PVI-SLP-B Vent Components Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 62 60 FT PV Wire Harness PVI-WH60 80 FT PV Wire Harness PVI-WH80 100 FT PV Wire Harness PVI-WH100 PVLP-HS PVLP-BEK Heat Shield Brick Kit Figure 12.7 PVLP-SLP Vent Components Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 63 1-1/2 in. 12 in. 5-1/2 in. 220 mm 38 mm 305 mm 146 mm SLP-WS SLP-FS Wall Shield Firestop Ceiling Firestop Figure 12.8 SLP Series Vent Components Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 64 12-5/8 IN. 10-5/8 IN. 59 mm 367 mm (321 mm) (270 mm) SLP-RDS SLP-WT-BK ROOF DECK INSULATION SHIELD Wall Thimble-Black Figure 12.9 SLP Series Vent Components Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 65 105 mm 318 mm SLP-TVHW Vertical Termination Cap 13-1/2 in. 4-3/4 in. 343 mm 121 mm SLK-SNKD Snorkel Termination Cap Figure 12.10 SLP Series Vent Components Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...
  • Page 66: Accessories

    Please contact your Heat & Glo dealer with any questions or concerns. For the location of your nearest Heat & Glo dealer, please visit www.heatnglo.com. Printed in U.S.A. - Copyright 2020 Heat & Glo • 6000CMOD-IFT, 8000CMOD-IFT Installation Manual • 2509-980 Rev. L • 6/20...