Electrical Information; Wiring Requirements; Intellifire Plus; Tm Ignition System Wiring - Heat & Glo 6000CLX-IPI-T Owner's Manual

Natural gas
Hide thumbs Also See for Heat & Glo 6000CLX-IPI-T:
Table of Contents

Advertisement

12
12

Electrical Information

A. Wiring Requirements
NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with National Electric Code
ANSI/NFPA 70-latest edition or the Canadian Electric
Code CSA C22.1.
• Wire the appliance junction box to 110-120 VAC. This is
required for use of optional accessories (standing pilot
ignition) or proper operation of the appliance (IntelliFire
Plus
TM
ignition).
• A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in locations such as in bathrooms or near
sinks.
• Low voltage and 110 VAC voltage cannot be shared
within the same wall box.
WARNING! Risk of Shock or Explosion! DO NOT wire
110V to the valve or to the appliance wall switch. Incorrect
wiring will damage controls.
TO JUNCTION
BOX (110V)
MODULATION
Figure 12.1 IPI Wiring Diagram
Heat & Glo • 6000CLX-IPI-S, 6000CLX-IPI-T, 8000CLX-S, 8000CLX-IPI-T • 2166-900 Rev. G • 12/09
FLAME
SENSE
MODULE
I
S
FLAME
FRONT EMBER LIGHTING (X 3)
B. IntelliFire Plus
• Wire the appliance junction box to 110-120 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 12.1, IPI Wiring Diagram.
• This appliance is equipped with an IntelliFire Plus
control valve which operates on a 6 volt/1.5 AMP
system.
• Plug the 6 volt transformer plug into the appliance junction
box to supply power to the unit OR install 4 AA cell
batteries (not included) into the battery pack before use.
C. Optional Accessories Requirements
• This appliance may be used with a wall switch, wall
mounted thermostat and/or a remote control.
Wiring for optional Hearth & Home Technologies approved
accessories should be done now to avoid reconstruction.
Follow instructions that come with those accessories.
Use only IntelliFire Plus™ Wireless Controls or WSK-21
wired wall switch with the IntelliFire Plus™ Ignition Sys-
tem.
IGNITER
3 PRONG 110VAC
AUX300 MODULE
AUX2 NOT USED FOR 6000/8000 MODELS.
BATTERY PACK
6V DC (AA X 4)
LED CONTROL
TM
Ignition System Wiring
RC300 4.5V DC
(AA X 3)
PROTECTIVE COVER INCLUDED
TO JUNCTION
BOX 110VAC
REAR ACCENT LIGHTING (X 2)
TM
49