Heat & Glo 6000C-IPI Owner's Manual
Hide thumbs Also See for 6000C-IPI:
Table of Contents

Advertisement

Models:
6000C-IPI
6000C-IPILP
8000C-IPI
8000C-IPILP
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death, or
property damage.
• DO NOT store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Leave the building immediately.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15
Pour demander un exemplaire en français de ce Manuel
du propriétaire, visitez www.heatnglo.com/translations.
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for use
and operation.
DANGER
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
A barrier designed to reduce the risk of
burns from the hot viewing glass is provided
with this appliance and shall be installed for
the protection of children and other at-risk
individuals.
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certifi ed kit is used.
HOT GLASS WILL
CAUSE BURNS.
UNTIL COOLED.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo 6000C-IPI

  • Page 1 See Table of Contents for location of additional Commonwealth gases, unless a certifi ed kit is used. of Massachusetts requirements. Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 2: Congratulations

    00,000 00,000 00,000 00,000 MIN. MIN. INPUT INPUT BTUH: BTUH: 00,000 00,000 00,000 00,000 Serial Serial XXXXXXXX XXXXXXXX ORIFICE ORIFICE SIZE: SIZE: #XXXXX #XXXXX #XXXXX #XXXXX (Serie): (Serie): Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 3: Table Of Contents

    E. Junction Box Installation......53 F. Wall Switch Installation for Fan (Optional) ... . 53 Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 4 D. Contact Information ......88  = Contains updated information. Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 5: Limited Lifetime Warranty

    3 years Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645H 10/15 Page 1 of 2 Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 6 THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645H 10/15 Page 2 of 2 Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 7: Listing And Code Approvals

    • A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks. Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 8: Requirements For The Commonwealth Of Massachusetts

    VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- of the installation. STRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 9: User Guide

    • Keep remote controls out of reach of children. GRATE SECTION 3.C. • Never leave children alone near a hot fi replace, whether Figure 2.1 General Operating Parts operating or cooling down. Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 10: Fan Kit (Optional)

    For more information refer to the instructions supplied with your decorative front. F. Fixed Glass Assembly See Section 14.H. Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 11: Ipi Battery Tray/Battery Installation

    WARNING! Risk of Fire or Asphyxiation! DO NOT op- Batteries should only be installed for use during power erate fi replace with fi xed glass assembly removed. outages. See Section H. Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 12: Lighting Instructions (Ipi)

    Keep burner and control compartment clean. See installation and operating instruc- Propane Installation code, CSA B149.1. tions accompanying appliance. For additional information on operating your 593-913i Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 13: After Fireplace Is Lit

    Is it normal to see the pilot fl ame burn turned off. Some optional control systems available with IPI models may allow pilot fl ame to continually? remain lit. Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 14: Maintenance And Service

    • Carefully set fi xed glass assembly in place on fi replace. Hold glass in place with one hand and secure glass latches with the other hand. • Reinstall decorative front. Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 15: Maintenance Tasks-Qualifi Ed Service Technician

    • Inspect for paint condition, warped surfaces, corrosion or perforation. Sand and repaint as necessary. • Replace fi replace if fi rebox has been perforated. Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 16: Refractory, Grate And Valve Assembly Removal

    Note: The base refractory must be assembly. removed to access screws. BASE REFRACTORY Figure 3.4 Base Refractory Removal Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 17: Burner Identifi Cation/Verifi Cation

    See Figure 3.5 for burner identifi cation chart. Notch patterns are located on bottom side of burner. NOTCH LOCATION 6000CL 6000CLX 8000CL 8000CLX Figure 3.5 Burner Identifi cation Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 18: Installer Guide

    FRAMING HEADED OFF IN CEILING JOISTS (SECTION 8.C) OPTIONAL WALL SWITCH MANTEL AND MANTEL LEG (SECTION 5.D) SURROUND HEARTH EXTENSION GAS LINE (SECTION 11) Figure 4.1 Typical System Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 19: Design And Installation Considerations

    Flat blade screwdriver 1/2 - 3/4 in. length, #6 or #8 Self-drilling screws Caulking material (300ºF minimum continuous exposure rating) One 1/4 in. female connection (for optional fan). Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 20: Framing And Clearances

    See Section D. 6000 Mantel Projections 1295 1067 1829 1438 55-7/8 61-1/2 19-3/4 See Section D. 8000 Mantel Projections 1419 1245 2007 1562 Figure 5.1 Appliance Locations - 6000 Models Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 21: Constructing The Appliance Chase

    1019 1245 * Adjust framing dimensions for interior sheathing (such as sheetrock) C** Add 12 inches for rear venting with one 90º elbow. Figure 5.2 Clearances to Combustibles Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 22: Mantel And Wall Projections

    Note: All measurements in inches. Note: Measurement is taken from top of the opening, NOT the top of the fi replace. Figure 5.3 Minimum Vertical and Maximum Horizontal Dimensions Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 23: Termination Locations

    Over 16/12 to 18/12 ..........7.0 Over 18/12 to 20/12 ..........7.5 Over 20/12 to 21/12 ..........8.0 * 3 foot minimum in snow regions Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 24 2 sides beneath the fl oor. venting system does not meet these requirements. Figure 6.3 Minimum Clearances for Termination • Vinyl protection kits are suggested for use with vinyl siding. Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 25: Vent Information And Diagrams

    DVP6 Effective Height/Length DVP12 DVP24 DVP36 DVP48 1219 DVP6A 3 to 6 76 to 152 DVP12A 3 to 12 76 to 305 Figure 7.2 DVP Pipe Effective Length Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 26: Vent Diagrams

    90º elbow, to allow the vent pipe to clear the top standoffs. Figure 7.3 Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 27 914 mm 16 ft * 4.9 m* 3 ft. 914 mm 14 ft.* 4.3 m* = 20 ft. (6.1 m) Maximum = 40 ft. (12.2 m) Maximum Figure 7.5 Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 28 TOP VENT REAR VENT Vertical 4 ft. Restrictor Restrictor Restrictor 8 ft. Restrictor 15 ft. Figure 7.6 20 ft. 25 ft. 30 ft. 35 ft. 40 ft. Figure 7.8 Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 29 1.2 m 20 ft. 6.1 m = 50 ft. (15.2 m) Maximum *No specifi c restrictions on this value EXCEPT cannot exceed 50 ft (15.2 m) Figure 7.10 Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 30 = 20 ft. (6.1 m) Maximum = 40 ft. (12.2 m) Maximum * No specifi c restrictions on this value EXCEPT V cannot exceed 40 ft. (12.2 m). INSTALLED HORIZONTALLY Figure 7.12 Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 31: Rear Vent - Horizontal Termination

    = 16 in. (406 mm) Maximum No Elbow Figure 7.13 One 45º Elbow Do not use a 45º elbow in corner installations. Use two 90º elbows instead. Figure 7.14 Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 32 12 ft. 3.7 m 15 ft. 4.6 m = 40 ft. (12.2 m) Maximum = 3 ft. (914 mm) Maximum = 20 ft. (6.1 m) Maximum Figure 7.16 Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 33 12 ft. 3.7 m 8 ft. 2.4 m 15 ft. 4.6 m = 40 ft. (12.2 m) Maximum = 15 ft. (4.6 m) Maximum INSTALLED HORIZONTALLY Figure 7.18 Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 34 = 40 ft. (12.2 m) Maximum *No specifi c restrictions on this value EXCEPT cannot exceed 40 ft. (12.2 m) Maximum = 8 ft. (2.4 m) Maximum INSTALLED Figure 7.20 HORIZONTALLY Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 35: Coaxial To Colinear Venting

    CAUTION! DO NOT use any fl ue restrictor when vent- ing with the DV-46DVA-GCL adapter and LINK-DV30B kit. This may result in poor fl ame appearance, sooting, pilot malfunction, or overheating. Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 36: Rear Vent

    10 ft. 3.05 m 0 ft. 0 mm Minimum 10 ft. 3.05 m Maximum 40 ft. 12.2 m 2 ft. 610 mm Maximum 40 ft. 12.2 m Figure 7.23 Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 37: Vent Clearances And Framing

    * Shows center of vent framing hole for top or rear venting. The center of the hole is one (1) in. (25.4 mm) above the center of the horizontal vent pipe. Figure 8.2 Wall Penetration Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 38: Install The Ceiling Firestop

    INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 8.4 Installing the Attic Shield Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 39: Installing The Optional Heat-Zone Gas Kit

    • Determine the location for the air register/fan housing assembly. Reference the Heat-Zone® Gas kit instructions for the remaining installation steps. HEAT-ZONE ® ATTACHES HERE Figure 8.5 Heat-Zone Cover Plate ® Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 40: Appliance Preparation

    Figure 9.2 Remove the white gasket material covering the seal cap. Figure 9.5 Remove the insulation from the outer vent pipe. For rear venting there is no insulation in the outer vent pipe. Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 41: Rear Vent

    (90º) and remove the insulation gasket. Figure 9.10 Discard the vent cap, remove and discard the insulation basket. Figure 9.8 Cut the metal retaining band and fold the sides out. Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 42: Installing The Non-Combustible Board

    • Bend out nailing tabs on each side. Figure 9.14 Proper Positioning and Securing of an Appliance • Place the appliance into position. Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 43: Installing Vent Pipe (Dvp And Slp Pipe)

    fl ue at the horizontal elbow joint to prevent the elbow from rotating. Use screws no longer than 1/2 in. (13 mm). If predrilling screw holes, DO NOT penetrate inner pipe. INCORRECT Figure 10.4 Seams Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 44: Assemble Vent Sections (Slp Pipe Only)

    • Only outer pipes are sealed, sealing the inner fl ue is not required. • All unit collar, pipe, slip section, elbow and cap outer fl ues shall be sealed. Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 45: Secure The Vent Sections

    Figure 10.10 Rotate Seams for Disassembly connection point to appliance. 120º Figure 10.11 Align and Disassemble Vent Sections Figure 10.8 Securing Vertical Pipe Sections 120º Figure 10.9 Securing Horizontal Pipe Sections Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 46: Install Decorative Ceiling Components (Slp Only)

    fl aps and the roof. Figure 10.13 WARNING! Risk of Fire! Clean out ALL materials from inside the support box and complete the vertical vent run and termination. Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 47: Install Metal Roof Flashing

    • Caulk the perimeter of the fl ashing where it contacts the roof surface. See Figure 10.15. • Caulk the overlap seam of any exposed pipe sections that are located above the roof line. Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 48: Install Vertical Termination Cap

    • Once the pipe section and the termination cap have been connected, slide the wall thimble up to the interior wall surface and attach with screws provided. See Figure 10.18. Figure 10.18 Wall Thimble Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 49: Install Horizontal Termination Cap (Dvp And Slp Pipe)

    DVP-TRAP1 can adjust 1-1/2 in. (3-1/8 to 4-5/8 in.) DVP-TRAP2 can adjust 4 in. (5-3/8 to 9-3/8) DVP-HPC1 can adjust 2-1/8 in. (4-1/4 to 6-3/8) DVP-HPC2 can adjust 4-1/8 in. (6-3/8 to 10-1/2) Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 50: Gas Information

    fl exible gas connector are connected to the 1/2 in. (13 mm) control valve inlet. • If substituting for these components, please consult local codes for compliance. Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 51: Electrical Information

    • A red or black ignitor button (as shown in Figure 12.1) indicates this appliance is standing pilot ignition. RED OR BLACK BUTTON Figure 12.1 Ignitor Button Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 52 SENSE TO JUNCTION BOX (110V) MODULE FLAME MODULATION RC100 RC200 (OPTIONAL WALL CONTROLS) BATTERY PACK 6V DC THERMOSTAT WIRE ASSEMBLY/ WALL SWITCH WIRE Figure 12.2 IPI Wiring Diagram Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 53: Optional Accessories Requirements

    • Add a 1/4 in. insulated female connector to the red (switch leg) wire, route it through the knockout in the face of the junction box, and connect to the top fan switch connector (1/4 in. male) as shown. Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 54: Finishing

    1060 1219 Inches Millimeters Figure 13.3 Noncombustible Facing Diagram  Inches  Millimeters Figure 13.2 Clearances to Mantel Leg or Wall Projections (Acceptable on both sides of opening) Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 55: Decorative Fronts

    They must be removed following fi nishing work. See fi gure 13.7. Figure 13.4 Finishing Material 1 Inch Thick or Less Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 56 B = Top of decorative front to bottom of fi replace. D = Bottom of Finishing Material to Bottom of Fireplace Figure 13.5 Finishing Material Thickness Greater Than One Inch Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 57 Figure 13.7 Removing Finishing Strips. 31-7/16 in. (6000) 33-5/16 in. (8000) 4-5/8 in. (6000/8000) 35-13/16 in. (6000) 42-3/4 in. (8000)  Figure 13.8. Clean Face Decorative Front Dimensions Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 58: Elevated Hearth Systems

    Note 1. Add dimensions to Wall Penetration (Figure 8.2) and Rough Opening Height (Figure 5.2). Note 2. Verify Marble Cut Lengths on site prior to cutting. Note 3. Dimensions assume use of a 3/4 in. Hearth Pad. Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 59: Appliance Setup

    Figure 14.2 Placement of Embers BEND TABS UP AIR SCOOP PILOT COVER BURNER ASSEMBLY BURNER SHIELD GUIDE SLEEVES Figure 14.3 Embers Overlapping Burner Port Holes (LP only). Figure 14.1 Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 60: Install The Log Assembly

    fi tted together, mate the groove located on the bottom of Log #2 with the horizontal grate bar and slide Log # 2 toward the left until it rests against the far left grate tine. Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 61 Ensure the log set is in proper position by measuring from the front of Log #1 to the refractory as shown in Figure 11. The measurement will be 6 inches if logs are placed properly. Figure 11 2164-935D Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 62 After slot and tab have been fi tted together, mate the groove located on the bottom of Log #2 with the horizontal grate bar and slide Log # 2 toward the left until it rests against the far left grate tine. Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 63 Figure 10. Set the other end of Log #6 on the fl at area located on top of Log #4 (see Figure 9). Log #6 will also rest against center grate tine. When properly installed, Log #6 will rest securely on all 3 contact points, not allowing movement or shifting. 2168-935C Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 64: Fixed Glass Assembly

    • Install optional trim kits and/or surrounds using the instructions included with the accessory. • Use non-combustible materials to cover the gap between the sheet rock and the appliance (when applicable to the model). Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 65: Troubleshooting

    D. Pilot valve solenoid Verify that 1.5 to 1.8 VDC is supplied to pilot solenoid from module. If below 1.5 volts, replace module. If 1.5 volts or greater, replace valve. Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 66 fl ame sensing rod. Verify continuity with a multi-meter with ohms set at lowest range. Replace pilot if any damage is detected. Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 67: Reference Materials

    Millimeters Location Inches Millimeters 1041 11-11/16 36-1/8 33-1/2 28-1/2 14-1/4 34-5/8 2-1/4 8-1/2 2-7/8 9-11/16 26-7/8 8-1/2 6 dia 39-7/8 1013 40-7/8 1038 Figure 16.1 Appliance Dimensions-6000 Models Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 68 Inches Millimeters Location Inches Millimeters 1219 11-11/16 43-1/8 1096 35-1/2 35-1/2 17-3/4 36-5/8 2-3/8 8-1/2 2-7/8 9-15/16 8-1/2 28-7/8 42-7/8 1089 41-7/8 1064 Figure 16.2 Appliance Dimensions-8000 Models Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 69 32-7/16 20-1/2 37-1/16 1-1/4 7-11/16 32-7/8 34-1/16 6000 ARC-36 39-7/16 22-7/16 44-1/16 1-1/4 7-7/16 34-13/16 8000 ARC-42 1002 1119 Figure 16.3 Decorative Front Dimensions - Folio and Arcadia Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 70 20-1/2 32-7/16 37-5/16 1-1/2 7-7/8 32-7/8 34-1/8 6000 CHA-36 22-7/16 39-7/16 44-1/16 1-1/4 7-7/16 34-13/16 8000 CHA-42 1002 1119 Figure 16.4 Decorative Front Dimensions - Halston and Chateau Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 71 31-9/16 20-7/8 37-1/8 1-1/4 7-3/4 32-7/8 34-1/16 6000 GALLERIA-6 38-9/16 22-3/4 44-1/16 1-1/4 7-3/4 34-3/4 8000 GALLERIA-8 1121 Figure 16.5 Decorative Front Dimensions - Chateau Forge and Galleria Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 72 CLEAN FACE DECORATIVE FRONTS 31-9/16 22-1/8 35-13/16 4-5/8 6-15/16 26-3/4 31-7/16 6000 CF-36 38-1/2 24-1/16 42-3/4 4-5/8 6-15/16 28-11/16 33-5/16 8000 CF-42 1086 Figure 16.6 Decorative Front Dimensions Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 73: Vent Components Diagrams

    14 in. (356 mm) 5 in. 12 in. (127 mm) (305 mm) 6 in. (152 mm) DVP-HVS (Vent Support) DVP-WS (Wall Shield Firestop) Figure 16.7 DVP Vent Components Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 74 79 mm 117 mm Length DVP-TRAP 5-3/8 in. 9-3/8 in. Trap2 Horizontal Termination Cap 137 mm 238 mm DVP-TRAP2 DVP-TRAP1 DVP-TRAPK2 DVP-TRAPK1 DVP-HPC1 DVP-HPC2 Figure 16.8 DVP Vent Components Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 75 13-7/8 in. 9-1/2 in. 26 in. (352 mm) (241 mm) 660 mm 14 in. (356 mm) DVP-HSM-B Extended Heat Shield DRC-RADIUS Figure 16.9 DVP Vent Components Cap Shield Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 76 7-3/4 to 10-3/8 in. (222 mm) (197 to 264 mm) DVP-FBHT 1-5/8 in. (41 mm) FireBrickTermination Cap DVP High Performance Cap LINK-DV-30B (LINK-DV-30) Figure 16.10 DVP Vent Components Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 77 (233 mm) 13-5/8 in. 16-11/16 in. 16-11/16 in. (346 mm) (424 mm) 424 mm 12-1/2 in. (318 mm) SLP-LPC SLP Low Profi le Cap Figure 16.11 Vent Components Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 78 DVP-HRC-ZC-SS HORIZONTAL TERMINATION CAP COAXIAL to COLINEAR VENTING LINK-DV30B 768-380A DV-46DVA-GCL Flex Liner Kit Stainless Steel Flex Pipe Coaxial/Colinear Appliance Connector DVP-2SL Adapter Figure 16.12 DVP Vent Components Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 79 Use if the PVLP-SLP is installed in a high traffi c 80 FT PV Wire Harness PVI-WH80 area. 100 FT PV Wire Harness PVI-WH100 PVLP-HS PVLP-BEK Heat Shield Brick Kit Figure 16.13 PVLP-SLP Vent Components Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 80 8-11/16 in. 1-1/2 in. 5-1/2 in. 12 in. 220 mm 38 mm 305 mm 146 mm SLP-WS SLP-FS Wall Shield Firestop Ceiling Firestop Figure 16.14 SLP Series Vent Components Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 81 13-1/2 in. 330 mm 343 mm 1-5/16 in. 13 in. 34 mm 330 mm SLK-SNKD Snorkel SLP-DCF-BK Termination Cap Ceiling Firestop Black Figure 16.15 SLP Series Vent Components Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 82: Service Parts

    Air Cover 2164-144 Glass Door Assembly GLA-6000G Surround Assembly 2166-019 Finishing Strips (Sold as kit only) SRVFS-6 Junction Box 4021-013 10/15 Additional service part numbers appear on following page. Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 83 582-850 **Fuse for battery pack can be sourced locally, not a warranty item. Specs are 250v, 1A fuse, 3/4” long Additional service part numbers appear on following page. Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 84: Service Parts

    Touch Up Paint TUP-GBK-12 Conversion Kit NG NGKI-6C Conversion Kit LP LPKI-6C Regulator NG NGK-DXV-50 Regulator LP LPK-DXV-50 Pilot Ori ce NG 593-528 Pilot Ori ce LP 593-527 Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 85: Log Set Assembly

    Refractory Basket 2170-108 Glass Door Assembly GLA-950TR Surround Assembly 2170-019 Finishing Strips (Sold as kit only) SRVFS-8 Junction Box 4021-013 Additional service part numbers appear on following page. 10/15 Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 86 582-850 **Fuse for battery pack can be sourced locally, not a warranty item. Specs are 250v, 1A fuse, 3/4" long Additional service part numbers appear on following page. Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 87 Touch Up Paint TUP-GBK-12 Conversion Kit NG NGKI-8C Conversion Kit LP LPKI-8C Regulator NG NGK-DXV-50 Regulator LP LPK-DXV-50 Pilot Ori ce NG 593-528 Pilot Ori ce LP 593-527 Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...
  • Page 88: Contact Information

    5941237, 6006743, 6019099, 6053165, 6145502, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729, 8147240 or other U.S. and foreign patents pending. 2000-945C Printed in U.S.A. - Copyright 2015 Heat & Glo • 6000C-IPI, 8000C-IPI • 2164-900 Rev. AB • 10/15...

This manual is also suitable for:

8000c-ipilp6000c-ipilp8000c-ipi

Table of Contents