Appendix C – System Specifications
C.1
Physical
Width:
Depth:
Height:
Rack size:
Weight fully loaded:
C.2
Environmental
Operating temperature range:
Operating humidity range:
Storage temperature range:
Storage humidity range:
Heat generated in normal operation:
C.3
Electrical
Both the AC and DC power versions of the ConsoleServer feature redundant power
supplies.
C.3.1 AC Power
Universal input voltage, auto-switched AC power supplies, switch fused
Input voltage:
AC frequency:
Maximum power consumption:
Typical power consumption:
C.3.2 DC Power
48 volt only, externally fused
Input voltage:
Maximum power consumption:
Typical power consumption:
17.25 inches (43.82 cm)
14.75 inches (37.47 cm)
5.25 inches (13.34 cm)
3u high, mounts in EIA-standard 19-inch rack
20 lbs. (9.08 kg)
32°F (0°C) to 125°F (52°C)
30% to 90% RH, non-condensing
-4°F (-20°C) to 158°F (70°C)
10% to 90% RH, non-condensing
170.6 BTU/hr
115/230 VAC
50/60 Hz
65 W
50 W
-48 VDC
65 W
50 W