FUEL SYSTEM
Injection pump delivery check on test bench
1 Delivery control rack rod
2 Rack rod 1 in stop position
3 Rack rod 1 in max. delivery position
A = 18-19 mm (max.rack rod stroke)
α = 66°
113
Static injection timing
Disconnect pipe 1 from injection pump and close it, to avoid fuel lea-
kages.
Mount in its place a nylon pipe 2 as shown in the picture. Insert in this
pipe an iron wire and let it project by approximately 10 mm: in this way
any drop in fuel can easily be checked.