Timing angles for operation (0.15 valve play).

For KD 225
α
= 6° before A corresponding to 12 mm
β
= 22° after B corresponding to 44 mm
γ
= 58° before B corresponding to 116 mm
δ
= 10° after A corresponding to 20 mm.
Values measured on the circumference of the flywheel D = 230 (one
degree corresponds to 2 mm).
For KD 315 - 350
α
= 10° before A corresponding to 20.09 mm
β
= 42° after B corresponding to 87.78 mm
γ
= 58° before B corresponding to 121.22 mm
δ
= 10° after A corresponding to 20.9 mm.
Values measured on the circumference of the flywheel D = 240 (one
degree corresponds to 2.09 mm).

Timing angles for inspection (0.65-0.70 valve play).

For KD 225
α
= 7° after A corresponding to 14 mm
β
= 9° after B corresponding to 18 mm
γ
= 45° before B corresponding to 90 mm
δ
= 3° before A corresponding to 6 mm.
Values measured on the circumference of the flywheel D = 230 (one
degree corresponds to 2 mm).
For KD 315 - 350
α
= 1° after A corresponding to 2.09 mm
β
= 31° after B corresponding to 64.79 mm
γ
= 45° before B corresponding to 94.05 mm
δ
= 3° before A corresponding to 6.27 mm.
Values measured on the circumference of the flywheel D = 240 (one
degree corresponds to 2.09 mm).