Rotary Switch Positions
Switch
Position
Automatically selects ac or dc volts based on the sensed input with a low
x
impedance input.
e
AC voltage from 0.06 mV to 600 V.
Frequency from 5 Hz to 50 kHz.
Hz (button)
D
DC voltage from .001 V to 600 V.
AC voltage from 6.0 to 600 mV, dc-coupled. DC voltage from 0.1 to 600 mV.
l
Ohms from 0.1
s
Continuity beeper turns on at 20
R
Diode Test. Displays OL above 2.0 V.
S
Farads from 1 nF to 9999 F.
j
AC current from 0.1 to 10 A (>10 to 20 A, 30 seconds on, 10 minutes off).
10.00 A display flashes. 20 A, OL is displayed. DC-coupled.
Hz (button)
Frequency from 45 Hz to 5 kHz.
DC current from 0.001 A to 10 A (>10 to 20 A, 30 seconds on, 10 minutes off).
I
10.00 A display flashes.
w
Non-contact sensing of ac voltage.
Note: All ac functions and Auto-V LoZ are true-rms. AC voltage is ac-coupled. Auto-V LoZ, AC mV and AC
amps are dc coupled.
Measurement Function
to 40 M .
and turns off at 250 .
20 A, OL is displayed.
True-rms Multimeters
Rotary Switch Positions
Model
117C
115C & 117C
115C & 117C
115C & 117C
115C & 117C
115C & 117C
115C & 117C
115C & 117C
115C & 117C
115C & 117C
115C & 117C
117C
7
Need help?
Do you have a question about the 115C and is the answer not in the manual?
Questions and answers