Fluke 115 digital multimeter specifications

Advertisement

Quick Links

Fluke 115
Multimeter
Actual size
R
N10140

Technical Data

Compact true-rms meter for
field service technicians
The Fluke 115 is the solution for a wide
variety of electrical and electronic test-
ing applications. This true-rms meter
provides easy one-handed operation in
a compact package.
Features include:
Resistance, continuity, frequency, capacitance, and diode test
Measures 20 A (30 seconds momentary; 10 A continuous)
Large white LED backlight to work in poorly lit areas
Compact ergonomic design for one-handed operation
Compatible with optional magnetic hanger (ToolPak
True-rms for accurate measurements on non-linear loads
Min/Max/Average with elapsed time to record signal
fluctuations
CAT III 600 V safety rated

General specifications

Accuracy is specified for 1 year after calibration, at operating
temperatures of 18 °C to 28 °C, with relative humidity at
0 % to 95 %.
The accuracy specifications take the form of:
± ( [ % of reading ] + [ counts ] )
Maximum voltage between any
terminal and earth ground
Surge protection
Fuse for A input
Display
Bar graph
Operating temperature
Storage temperature
Battery
Battery life
)
600 V
6 kV peak per IEC 61010-1 600 V
CAT III, Pollution Degree 2
11 A, 1000 V FAST Fuse
(Fluke PN 803293)
Digital: 6,000 counts, updates 4/sec
33 segments, updates 32/sec
-10 °C to + 50 °C
-40 °C to + 60 °C
9 volt Alkaline, NEDA 1604A/
IEC 6LR61
400 hours typical, without backlight

Advertisement

loading

Summary of Contents for Fluke 115

  • Page 1: Technical Data

    Fluke 115 Multimeter Technical Data Compact true-rms meter for field service technicians The Fluke 115 is the solution for a wide variety of electrical and electronic test- ing applications. This true-rms meter provides easy one-handed operation in a compact package.
  • Page 2 0.001 A 1.5 % + 3 (45 Hz to 500 Hz) 10.00 A 0.01 A 20 A continuous overload for 30 seconds max. DC amps 6.000 A 0.001 A 1.0 % + 3 10.00 A 0.01 A 20 A continuous overload for 30 seconds max. Fluke. Keeping your world up and running. Hz (V or A input) 99.99 Hz 0.01 Hz 999.9 Hz 0.1 Hz 0.1 % + 2 Fluke Corporation 9.999 kHz 0.001 kHz PO Box 9090, Everett, WA USA 98206 50.00 kHz 0.01 kHz...