Fluke 114 User Manual

Fluke 114 User Manual

True-rms multimeters

Advertisement

info@Fluke-Direct.com
1.800.544.2843
PN 2572573
July 2006, Rev. 1, 2/07
© 2006, 2007 Fluke Corporation, All rights reserved. Printed in China
All product names are trademarks of their respective companies.
Fluke-Direct
www.calcert.com
15
10
20
5
25
0
30
114, 115, and 117
True-rms Multimeters
Users Manual
®
.com
1.888.610.7664
sales@calcert.com

Advertisement

Table of Contents
loading

Summary of Contents for Fluke 114

  • Page 1 ® 114, 115, and 117 True-rms Multimeters Users Manual PN 2572573 July 2006, Rev. 1, 2/07 © 2006, 2007 Fluke Corporation, All rights reserved. Printed in China All product names are trademarks of their respective companies. Fluke-Direct .com info@Fluke-Direct.com 1.888.610.7664 1.800.544.2843...
  • Page 2: Limited Warranty And Limitation Of Liability

    LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for three years from the date of purchase. This warranty does not cover fuses, disposable bat- teries, or damage from accident, neglect, misuse, alteration, contamination, or abnor- mal conditions of operation or handling.
  • Page 3 True-rms Multimeters Introduction Unsafe Voltage The Fluke Model 114, Model 115, and Model 117 are To alert you to the presence of a potentially hazardous voltage, the Y symbol is displayed when battery-powered, true-rms multimeters (hereafter "the the Meter measures a voltage ≥30 V or a voltage Meter") with a 6000-count display and a bar graph.
  • Page 4 114, 115, and 117 Users Manual Safety Information A "XWWarning" statement identifies hazardous conditions and actions that could cause bodily harm or death. A "WCaution" statement identifies conditions and actions that could damage the Meter or the equipment under test.
  • Page 5: Safety Information

    Check the test leads for continuity before use. Do not use if the readings are high or noisy. • Do not use the Auto Volts function to measure voltages in circuits that could be damaged by this function’s low input impedance (≈3 kΩ)(114 and 117 only). Symbols AC (Alternating Current)
  • Page 6 114, 115, and 117 Users Manual Display VoltAlert edy02f.eps Symbol Meaning Model The Meter is in the VoltAlert™ non-contact voltage detect mode. The Meter function is set to Continuity. 114, 115, & 117 The Meter function is set to Diode Test 115 &...
  • Page 7 True-rms Multimeters Display Display hold enabled. Display freezes present reading. 114, 115, & 117 MIN MAX AVG mode enabled. 114, 115, & 117 Maximum, minimum, average or present reading displayed (Red LED) Voltage presence through the non-contact VoltAlert sensor The Meter is measuring voltage or capacitance with a low input 114, 115 &...
  • Page 8 114, 115, and 117 Users Manual Terminals 10 A FUSED edy01f.eps Description Model Input terminal for measuring ac and dc current to 10 A. 115 & 117 Common (return) terminal for all measurements. 114, 115, & 117 Input terminal for measuring voltage, continuity, resistance, capacitance, 114, 115, &...
  • Page 9: Rotary Switch Positions

    Automatically selects ac or dc volts based on the sensed input with a low 114 & 117 impedance input. AC voltage from 0.06 to 600 V. 114, 115 & 117 Frequency from 5 Hz to 50 kHz. 115 & 117 Hz (button) DC voltage from .001 V to 600 V.
  • Page 10 114, 115, and 117 Users Manual Battery Saver ("Sleep Mode") Display HOLD XWWarning The Meter automatically enters "Sleep mode" and blanks the display if there is no function change, range change, or To avoid electric shock, when Display button press for 20 minutes. Pressing any button or HOLD is activated, be aware that the turning the rotary switch awakens the Meter.
  • Page 11: Power-Up Options

    Meter on. lead before removing the common test lead. Power-Up Options are canceled when you turn the Meter off and when sleep mode is activated. Fluke-Direct .com info@Fluke-Direct.com 1.888.610.7664 1.800.544.2843 www.calcert.com...
  • Page 12 114, 115, and 117 Users Manual Measuring Resistance Testing for Continuity edy06f.eps Note edy04f.eps XWWarning The continuity function works best as a fast, To avoid electric shock, injury, or convenient method to check for opens and damage to the Meter, disconnect shorts.
  • Page 13: Making Basic Measurements

    Measuring AC and DC Millivolts Millivolts AC Millivolts DC edy03f.eps Using Auto Volts Selection (114 & 117 only) With the function switch in the x position, the Meter edy18f.eps automatically selects a dc or ac voltage measurement based on the input applied between the V or + and COM jacks.
  • Page 14 114, 115, and 117 Users Manual Measuring AC or DC Current (115 & 117) XWWarning To avoid personal injury or damage to the Meter: • Never attempt to make an in-circuit current measurement when the open- circuit potential to earth is >600 V.
  • Page 15 Meter. Make sure the Meter has the correct function selected, AC or DC, for your current probe. Refer to a Fluke catalog or contact your local Fluke representative for compatible current clamps. edy05f.eps edy14f.eps...
  • Page 16 114, 115, and 117 Users Manual Press g to turn the frequency measurement function Measuring Frequency (115 & 117 only) on and off. Frequency works with ac functions only. XWWarning In frequency, the bar graph and range annunciator indicate To avoid electrical shock, disregard the bar the ac voltage or current present.
  • Page 17 Capacitance mode. In this mode, capacitance Open measurements will have a lower accuracy and lower Shorted dynamic range. This setting is not saved when the Meter is edy07f.eps turned off or goes into sleep mode. Fluke-Direct .com info@Fluke-Direct.com 1.888.610.7664 1.800.544.2843 www.calcert.com sales@calcert.com...
  • Page 18 114, 115, and 117 Users Manual Using the Bargraph Testing the Fuse (115 & 117 only) The bar graph is like the needle on an analog meter. It has Test fuse as shown below. an overload indicator (>) to the right and a polarity indicator (+)to the left.
  • Page 19: Maintenance

    The battery fits inside the battery door, which is then inserted into the case, bottom edge first, until it is fully seated. Do not attempt to install the battery directly into the case. 5. Install and tighten battery door screw. Fluke-Direct .com info@Fluke-Direct.com 1.888.610.7664 1.800.544.2843 www.calcert.com...
  • Page 20 5. Remove the fuse from its holder and replace it with an 11 A, 1000 V, FAST fuse having a minimum interrupt rating of 17,000 A. Use only Fluke PN 803293. 6. To re-assemble the Meter, first attach the case bottom to the case top, then install the two screws.
  • Page 21: General Specifications

    Surge Protection ............. 6 kV peak per IEC 61010-1 600V CAT III, Pollution Degree 2 W Fuse for A input (115 & 117 only): ....11 A, 1000 V FAST 17 kA Fuse (Fluke PN 803293) Display ..............Digital: 6,000 counts, updates 4/sec Bar Graph: 33 segments, updates 32/sec Temperature.............
  • Page 22 114, 115, and 117 Users Manual Certifications ............UL, , CSA, TÜV, N10140), VDE IP Rating (dust and water protection) IP42 ......Table 1. Accuracy Specifications Accuracy Function Range Resolution Model ± ([% of Reading] + [Counts]) 114, DC millivolts 600.0 mV 0.1 mV...
  • Page 23 Accuracy Function Range Resolution Model ± ([% of Reading] + [Counts]) Beeper on < 20 Ω, off > 250 Ω; 114, 115, 600 Ω 1 Ω Continuity detects opens or shorts of 500 μs or longer. 600.0 Ω 0.1 Ω...
  • Page 24 114, 115, and 117 Users Manual Table 1 Accuracy Specifications (cont.) Accuracy Function Range Resolution Model ± ([% of Reading] + [Counts]) 6.000 A 0.001 A AC Amps True- 10.00 A 0.01 A 1.5 % + 3 115, 117 20 A for 30 seconds max., (45 Hz to 500 Hz) 10 minutes rest min.
  • Page 25 Open Circuit Test Voltage Full Scale Voltage Current <350 μA Ohms <2.7 V dc To 6.0 MΩ 40 MΩ <0.7 V dc <0.9 V dc Diode Test <2.7 V dc 2.000 V dc <1.2 mA Fluke-Direct .com info@Fluke-Direct.com 1.888.610.7664 1.800.544.2843 www.calcert.com sales@calcert.com...