Rotary Switch Positions - Fluke 110 PLUS Manual

True-rms multimeters
Table of Contents

Advertisement

110 PLUS and 115
Users Manual

Rotary Switch Positions

Switch
Position
Automatically selects ac or dc volts based on the sensed input with a low impedance input.
AC voltage from 0.06 to 600 V.
Frequency from 5 Hz to 50 kHz.
Hz (button)
DC voltage from 0.001 V to 600 V.
AC voltage from 6.0 to 600 mV, dc-coupled. DC voltage from 0.1 to 600 mV.
Ω
Ohms from 0.1 Ω to 40 MΩ.
Continuity beeper turns on at <20 Ω and turns off at >250 Ω.
Diode Test. Displays OL above 2.0 V.
Farads from 1 nF to 9999 μF.
AC current from 0.1 A to 10 A (>10 to 20 A, 30 seconds on, 10 minutes off). >10.00 A display
flashes. >20 A, OL is displayed. DC-coupled.
Frequency from 45 Hz to 5 kHz.
Hz (button)
DC current from 0.001 A to 10 A (>10 to 20 A, 30 seconds on, 10 minutes off). >10.00 A display
flashes. >20 A, OL is displayed.
Note:
All ac functions and Auto-V LoZ are true-rms. AC voltage is ac-coupled. Auto-V LoZ, AC mV and AC amps are dc-coupled.
8
Measurement Function
Model
110 PLUS
110 PLUS, 115
115
110 PLUS, 115
110 PLUS, 115
110 PLUS, 115
110 PLUS, 115
115
115
115
115