Mounting Recommendations; General Guidelines; Sloped Ceiling Installations - Casablanca C19xxxK Owner's Manual

Heritage ii
Table of Contents

Advertisement

Before mounting your Casablanca fan, read the following helpful recommendations. The location of the fan, air circulation, and
fan size are all important factors to consider before installation.
Location
Ceiling fans have practical uses in almost every room in your home. We
suggest you follow these mounting recommendations as you decide where
to install your Casablanca fan.
• For safety reasons, the fan blades must be a minimum of 7' above the
floor.
• Do not locate the fan in a doorway or above a swinging door.
• In bedrooms, fans work best when mounted above the foot of the bed.
• Over pool tables, be sure to provide plenty of clearance to avoid damage
from pool cues.
• In kitchens, be sure to allow for open cupboard doors to clear the fan
blades.
• Do not install a fan close to or over a pool or spa. High humidity combined
with corrosive gases will destroy the finish and warp the blades.
Fan Size
Variable fan speed capability permits the use of a full-size 60" fan even in smaller rooms. For very large rooms, two fans may
be needed.
SUGGESTED EXTENSION DOWNROD LENGTHS
Ceiling Height
9' 0"
9' 6"
10' 0"
11' 0"
12' 0"
13' 0"
14' 0"
15' 0"
When to Use an Extension Downrod
For optimum performance and appearance, an
extension downrod should be used with your
Casablanca fan when installing on high (cathedral)
ceilings or sloped ceilings. Casablanca offers
standard downrods in increments of 6" up to 60". See
your Authorized Casablanca Dealer for details.
NOTE: The fan may wobble or vibrate if pole length is
not long enough and the inside blade is too close to
the downslope or side wall. Using a longer downrod
will usually solve the problem.
Calculation of Ceiling Angle
Use the tear-off Ceiling Angle Template card inserted
in this manual. It provides you with a simple "go" or
"no go" for installing your fan on a sloped ceiling.
6

MOUNTING RECOMMENDATIONS

GENERAL GUIDELINES

SLOPED CEILING INSTALLATIONS

Downrod Length
5"
5"
12"
18"
24"
36"
48"
60"
Maximum
Hang-Tru
®
Extension
angle 32º
Downrod
7' minimum
This slope is less than 32º.
EXAMPLE 1
It is OK to install your fan.
T his slope is 32º. This is the maxi-
mum slope that will allow the fan to
hang straight down. It is OK to install
EXAMPLE 2
your fan.
This slope is more than 32º. Your fan
will not hang straight down. Contact
your local Authorized Casablanca
Dealer.
EXAMPLE 3
Blades must be a
minimum of 7 feet
above the floor

Advertisement

Table of Contents
loading

Table of Contents