Safety and the proper operation of your Casablanca fan both require a thorough knowledge
of the product and proper installation; therefore, before attempting to install and operate your
Casablanca fan, read this owner's manual completely and carefully. Retain this manual for
future reference.
CAUTION: To avoid possible electrical shock, make certain that electricity is turned off
at the circuit breaker or fuse box before attempting any installation procedure.
Parts List __________________________________________________________________________2
Introduction _______________________________________________________________________5
Before You Start ................................................................................................................................................ 5
Safe Use ............................................................................................................................................................ 5
Mounting Recommendations .......................................................................................................................... 6
Sloped Ceiling Installation ............................................................................................................................... 6
Fan Installation ____________________________________________________________________7
Getting Started .................................................................................................................................................. 7
Mounting Bracket Installation .......................................................................................................................... 7
Fan Preparation ................................................................................................................................................. 8
Hanging the Fan ...............................................................................................................................................10
Wiring ............................................................................................................................................................... 11
Securing the Canopy .......................................................................................................................................12
Blade Installation .............................................................................................................................................13
W-74 Control Installation _________________________________________________________ 15
W-74 Wall Control Preparation ........................................................................................................................15
Installing the W-74 Wall Control ......................................................................................................................15
Single W-74 Installation ...................................................................................................................................15
Dual W-74 Installation ......................................................................................................................................16
W-74 Operation __________________________________________________________________ 17
Operation Power ..............................................................................................................................................17
Operation Speed Control ................................................................................................................................17
Operation Reversing Airflow ..........................................................................................................................17
Operation CFL Mode .......................................................................................................................................18
Changing Frequency Setting ..........................................................................................................................18
Operation Lights ..............................................................................................................................................18
Automatic Demonstration Program ...............................................................................................................19
Operation Safe-Exit® .......................................................................................................................................19
Operation Home-Safe® Program ................................................................................................................. 20
Operation Fan-Minder™ Program ................................................................................................................. 20
Light-minder® Program ................................................................................................................................. 20
Troubleshooting Tips _____________________________________________________________ 21
Care Recommendations __________________________________________________________ 22
Product Specifications ___________________________________________________________ 22
E
S
nErgy
READ AND SAVE THESE INSTRUCTIONS!
CONTENTS
P/N C6643001_ES
Owner's Manual
tar
RL0311
1

Advertisement

Table of Contents
loading

Summary of Contents for Casablanca Panama EnErgy Star C66U11B

  • Page 1: Table Of Contents

    READ AND SAVE THESE INSTRUCTIONS! Safety and the proper operation of your Casablanca fan both require a thorough knowledge of the product and proper installation; therefore, before attempting to install and operate your Casablanca fan, read this owner’s manual completely and carefully. Retain this manual for future reference.
  • Page 2: Parts List

    arts Parts List Item # Item Name Hanging System Canopy Trim Ring Ceiling Plate Omega Hardware Kit Wood Screw #10 Wood Screw #8 Washer Screw, 10-32 Receiver Large Wire Nut (Orange) Small Wire Nut (Blue) 3.0" Downrod and Ball Assembly Blade Iron Set Blade Iron Hardware Pack (Iron to Motor) #12 Screw...
  • Page 3 ® anama nErgy Model # C66U11B C66U45B C66U546B Asm. Dwg. # G1137-01 G1137-02 G1137-03 Finish Snow White Brushed Nickel Brushed Cocoa Qnty Part # Part # Part # 99411-03-000 99411-05-000 99411-09-000 G0151-01-000 G0151-01-000 G0151-03-000 89346-01-000 89346-01-000 89346-01-000 87942-24-203 87942-03-214 87942-03-546...
  • Page 4 PLEASE INSPECT ALL PACKAGING PRIOR TO DISCARDING! Your Casablanca fan was crafted with pride and care and inspected thoroughly prior to shipment. Before you begin to assemble and install your Casablanca fan, remove all parts from the carton and check them against the Parts Guide in this manual.
  • Page 5: Introduction

    • This fan is designed to be installed on an existing electrical outlet box. The outlet box must be UL Listed for ceiling fan installations. If it is not, a new box must be installed. Casablanca extension poles are available for sloped or high ceiling installations.
  • Page 6: Mounting Recommendations

    MOUNTING RECOMMENDATIONS Before mounting your Casablanca fan, read the following helpful recommendations. The location of the fan, air circulation, and fan size are all important factors to consider before installation. Location Ceiling fans have practical uses in almost every room in your home.
  • Page 7: Fan Installation

    If you do not have an existing fixture located After turning the power OFF at its source (either where you wish to place your Casablanca fan, the circuit breaker or fuse box), lower the old an approved ceiling fixture outlet box must be fixture and disconnect the wiring.
  • Page 8: Fan Preparation

    MOUNTING BRACKET INSTALLATION (CONT.) Step 1. Align the slotted holes in the ceiling plate with the pilot holes you drilled in the wood support structure. For proper alignment use slotted holes directly across from each other. Joist Note: The isolators should be flush against the ceiling.
  • Page 9 ® anama nErgy Step 3. Slide the Canopy, and Trim Ring on to the downrod, then route the wires through the 3.5" MOTOR WIRES Perma•Lock downrod and ball assembly as shown in PERMA•LOCK™ (LEAVE AT LEAST Figure #3. DOWNROD AND 6"...
  • Page 10: Hanging The Fan

    Step 5. Tighten the set screw as shown in Figure #5 to ensure safe operation of your fan. If it is tight enough, you should not be able to turn the downrod counterclockwise with your hands. If in doubt, tighten the set screw with until you cannot turn it any further.
  • Page 11: Wiring

    ® anama nErgy WIRING HARDWARE Orange Wire Caps (3) Blue Wire Caps (4) Receiver Trim Ring Canopy WIRING Power From Line Power Ceiling (IN) RED TAG Step 1. Locate the White wire marked "NEUTRAL IN" and connect it to the White Neutral Wire from your Line Neutral ceiling using one of the supplied orange wire caps.
  • Page 12: Securing The Canopy

    Step 5. Connect the White wire marked NEUTRAL OUT from the receiver and connect it to the White White-Neutral Wire coming from the fan with a blue wire cap. to Fan Step 6. Connect the Red wire marked FAN OUT from the receiver and connect it to the Red Wire coming from the fan with a blue wire cap.
  • Page 13: Blade Installation

    ® anama nErgy Keyhole Slot Round Step 10. Raise the Canopy over the Hanger Bracket. Hole Align the partially installed screws with the key slots in the canopy. Step 11. Twist the Canopy clockwise to secure. Step 12. Install the third & fourth canopy screws in the round holes on Canopy.
  • Page 14 Step 1. Attach a blade/blade iron assembly to the motor by using two blade iron screws provided. Place the end of the blade iron on the motor as shown in Figure 2. Insert the screws one by one using the provided screwdriver. Tighten securely by hand only.
  • Page 15: W-74 Control Installation

    PC board on the fan. INSTALLING THE W-74 WALL CONTROL NOTE: W-74 Wall Control should only be installed on Casablanca's Direct-Touch Fans. The wall control installs in the same manner as an ordinary light switch, using an existing wall box and wiring.
  • Page 16: Dual W-74 Installation

    2 BLACK WIRES W-74 NOTE: The RED wire is not used in this Wall Control application. DO NOT remove the crimped cap from the wire. Connect the green ground wire coming from the back of the W-74 control to the ground wire in the switch box.
  • Page 17: W-74 Operation

    Direct - Touch W-74 2 BLACK Wall Control 6. Remove the two remaining wires from the three-way WIRES switch. Connect one black wire of these wires to the black wire on the W-74 control. Secure the splice with a wire nut. The remaining wire is to be connected to the red wire on the W-74.
  • Page 18: Operation Cfl Mode

    SET TO ‘111111’ (Factory Setting) NOTE: DO NOT set dip switch setting in the remote (Figure 1) to ‘000000’, this may cause frequency interference from other Casablanca Products. All fans leave the factory set to DIP SWITCHES SET TO ‘000000’ “111111”...
  • Page 19: Automatic Demonstration Program

    Direct - Touch To change frequency: Turn power OFF at the circuit breaker or fuse box and at the toggle switch, for the fan you want to change. Remove the screws and switch plate from the existing switch box. Remove the screws holding the switch in the switch box. Pull the existing W-74 switch from the switch box to expose the dip switches located on the side of the control as shown in Figure #1.
  • Page 20: Operation Home-Safe® Program

    LIGHT-MINDER® PROGRAM The Light-Minder Program automatically turns OFF the fan mounted lights after two hours. To activate the Light-Minder Program: 1. Turn the power button off for at least 5 seconds. 2. Turn the on. Immediately press and hold the "1" button for 5 seconds. A series of tones will be heard indicating the command has been accepted.
  • Page 21: Troubleshooting Tips

    Consult the dealer or an experienced radio/TV technician for help. Note: Any changes or modifications to the transmitter or receiver not expressly approved by Casablanca Fan Company may void one’s authority to operate this remote control.
  • Page 22: Care Recommendations

    No Need for Lubrication • Never lubricate this fan! The precision motor at the heart of your Casablanca fan features sealed bearings that are lubricated for life.