INSTALLATION
ELECTRIC WIRING REQUIREMENTS
The cooker MUST be installed in compliance with:
Wiring connections in AS/NZS3000 wiring rules.
Local regulations, municipal building codes and other
statutory regulations.
Data plate – Gives information about the rating and
is located behind the bottom of the oven door.
Circuit diagram – Is located on the back panel of
the appliance.
For New Zealand only: The cooking range must be connected
to the supply by a supply cord fitted with the appropriately
rated plug that is compatible with the socket-outlet fitted to the
final sub-circuit in the fixed wiring that is intended to supply
this cooking range.
A functional switch MUST be provided near the appliance
in an accessible position (AS/NZS3000 – Clause 4.7.1).
Wiring MUST be protected against mechanical failure
(AS/NZS3000 – Clause 3.9).
The cooker requires a means of all pole disconnection
incorporated into the fixed wiring. This MUST have a
disconnection gap of 3mm.
The cooker MUST be properly earthed.
When connections are made to a multiphase 230/240V
supply, the bridge piece MUST be removed from between
the active connections.
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
IMPORTANT: Before you cook in your new oven it is
important that the protective oils used in the manufacture of
the product be removed. Refer to 'Before Operating your
Appliance for the First Time' in the Using The Oven section.
24
INSTALLATION
HARD WIRING
1. Remove rear panel.
2. Fit wires through hole at bottom centre using the appropriate
gland to protect insulation of wires from the hole edge.
Note that the secondary insulation of the wires will probably
need to be removed to fit through gland. If the conduit to
appliance is required to bend due to rear wall an elbow
may be required to achieve this.
3. Set the length of wiring from the gland to terminal block,
ensuring length is sufficient but not excessive.
4. Make connections to terminals and engage wires into plastic
clip. Cable tie as per diagram and secure plastic clip with
two long screws supplied.
5. Replace rear cover.
Glad
Plastic clip
Plastic screw
securing points
Cable tie