Mirage DSK-1 Manual page 54

Table of Contents

Advertisement

Sets the upper limit of the cutoff frequency for the current wavesample, regardless of any other
filter value (program, envelope, velocity).
72/Top Key (01-61)
Selects the highest key that will use the current wavesample. The TOP KEY values will
determine how many keys will use the wavesample. The highest TOP KEY of the lower
keyboard will determine the split point.
73/Sample Time Adjust (30-99)
This adjusts the rate at which the Mirage will sample. It is expressed in time between samples,
however, rather than rate. This parameter sets the time, in microseconds, between individual
samples. Combined with the SAMPLE START and SAMPLE END parameters, it will determine
the duration of the wavesample. The value is expressed in microseconds with VALUE 34
corresponding to the default sample rate of 29kHz and VALUE 99 corresponding to the
minimum sample rate of 10kHz. A higher number will yield a longer sample time, but with a
loss of audio quality.
74/Input Filter Frequency (00-99)
Filter cutoff frequency adjustment that will determine the maximum frequency that the Mirage
will allow through to the input when sampling. It is adjustable from 50Hz at VALUE 0 to 15kHz
at VALUE 99.
75/Line Level Input (On -Off)
Switching parameter to match the Mirage input to the sound source to be sampled in the current
wavesample. At VALUE OFF the input will accept mic level signals. At VALUE ON the input
will accept line level inputs. The best quality samples will always be obtained by setting this
parameter ON, and feeding the Mirage a line level signal from a mixer.
76/Sampling Threshold (00-63)
Adjusts the threshold level which the input signal must cross before the Mirage will begin
sampling. Pressing the SAMPLE UPPER or SAMPLE LOWER button will put the Mirage in the
"level detect" mode. Playing the sound to be sampled should light the middle bar in the display.
If the middle bar does not light, pressing CANCEL and then lowering the value number of this
parameter will lower the sampling threshold. After ENTER has been pressed, the first signal
above this threshold will automatically begin the sampling process. If this parameter is set to 0,
sampling will begin as soon as you press ENTER.
77/User Multisampling (On-Off)
Switching parameter to choose between user- selected sampling parameters and Mirage default
values. If this parameter is set to OFF, when sampling is initiated, the Mirage will automatically

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Mirage Mirage DSK-1

Table of Contents