No.
Crosswise compensation of needle entry
S040
of basting
This item sets the amount to move needle entry
position to the right or left when performing basting
more than two cycles.
S041
Compensation of left side position of bast-
ing
This item sets the amount to move the sewing
reference position of basting from the center of left
overedging to the right or left.
S042
Compensation of right side position of
basting
This item sets the amount to move the sewing
reference position of basting from the center of right
overedging to the right or left.
Speed setting of basting
S044
This item sets speed of basting.
Left parallel section tension
S051
This item sets needle thread tension at left parallel
section.
Right parallel section tension
S052
This item sets needle thread tension at right parallel
section.
Left parallel section tension (1st cycle of
S053
double stitching)
This item sets needle thread tension at left parallel
section of 1st cycle at the time of double stitching.
S054
Right parallel section tension (1st cycle of
double stitching)
This item sets needle thread tension at right parallel
section of 1st cycle at the time of double stitching.
S055
Tension at 1st bar-tacking section
This item sets needle thread tension at 1st bar-tack-
ing section.
S056
Tension at 2nd bar-tacking section
This item sets needle thread tension at 2nd
bar-tacking section.
S057
Setting of needle thread tension at the
start of sewing
This item sets needle thread tension of tie stitching
at the start of sewing.
Setting of needle thread tension of basting
S058
This item sets needle thread tension of basting.
ACT timing adjustment at the start of 1st
S059
bar-tacking
This item adjusts needle thread tension output start
timing at 1st bar-tacking section.
*1 : Displayed according to the shape
*2 : Displayed when it is set to with edit. Refer to "V-12. Method of setting sewing data with/without edit" p.32.
*3 : Displayed when the function is selected.
Item
– 36 –
Setting range
Edit unit
0.0 to 1.0
0.1 mm
-2.0 to 2.0
0.1 mm
-2.0 to 2.0
0.1 mm
400 to 4200
100 sti/min
0 to 200
1
0 to 200
1
0 to 200
1
0 to 200
1
0 to 200
1
0 to 200
1
0 to 200
1
0 to 200
1
-5 to 5
1 stitch
Remarks
*3
*2, *3
*2, *3
*3
*2
*2, *3
*2, *3
*2
*3
*2