6
SEARCH AND SCAN OPERATIONS
■ Other SCAN menu items
D Stop beep (STOP BEEP)
Selects the stop beep setting for scan.
• OFF : The stop beep is turned OFF.
• ON
: The receiver emits a long beep when a scan
pauses with signal is received.
D Scan pause timer (PAUSE)
Selects the scan pause time. When receiving signals, the
scan pauses according to the scan pause time.
• 2–20 SEC : Scan pauses for 2–20 sec. on a received
signal in 2 sec. steps.
• HOLD
: Scan pauses on a received signal until it
disappears. Rotate [DIAL] to resume man-
ually.
48
48
(default)
(default)
D Scan resume timer (RESUME)
Selects the scan resume time from a pause after the re-
ceived signal disappears.
• 0 SEC
: Scan resumes when a received signal disap-
pears.
• 1–5 SEC : Scan pauses 1–5 sec. after a received signal
disappears.
(default: 2 sec.)
• HOLD
: Scan remains paused on the received signal
according to the scan pause timer even if it
disappears. Rotate [DIAL] to resume manu-
ally.
Scan resume timer must be set shorter than scan pause
timer
, otherwise this timer does not activate.