Chapter 6 Basic Setting
Table 18 4-Port ONU Profile (continued)
LABEL
Speed
Duplex
Flow Control
Port-based VLAN
PVID
Forwarding Table
Upstream Priority Queue Size
Active
Queue 0 Size
Queue 1 Size
Queue 2 Size
Queue 3 Size
Downstream Priority Queue Size
Active
Queue 0 Size
Queue 1 Size
Queue 2 Size
Queue 3 Size
Add
Cancel
Clear
Name
Active
Delete
Cancel
76
DESCRIPTION
Select the link speed (10 or 100) in Mbps for the connection to the ONU.
Select the duplex mode (half or full) for the connection to the ONU.
IEEE 802.3x flow control is used in full duplex mode to send a pause signal to
the sending port, causing it to temporarily stop sending signals when the
receiving port memory buffers fill.
Select this option to enable flow control for the connection to the ONU.
This field displays the number of the port on the ONU.
Enter the port's VLAN ID (between 1 and 4094). A VLAN tag reflecting the
PVID is inserted in the frame forwarded through the port.
Note: The ports must be in the same VLAN group to
communicate with each other.
Select the outgoing port(s) (in the Forwarding Table) through which traffic
from the port (in the Port-based VLAN field) is allowed to go.
To allow two ports to talk to each other, you must define the outgoing port for
both ports.
Select Active to set the queue size for the upstream traffic.
Specify the size (in byte) for queue 0.
The number you entered is multiplied by 128.
Specify the size (in byte) for queue 1.
The number you entered is multiplied by 128.
Specify the size (in byte) for queue 2.
The number you entered is multiplied by 128.
Specify the size (in byte) for queue 3.
The number you entered is multiplied by 128.
Select Active to set the queue size for the downstream traffic.
Specify the size (in byte) for queue 0.
The number you entered is multiplied by 128.
Specify the size (in byte) for queue 1.
The number you entered is multiplied by 128.
Specify the size (in byte) for queue 2.
The number you entered is multiplied by 128.
Specify the size (in byte) for queue 3.
The number you entered is multiplied by 128.
Click Apply to save the settings.
Click Cancel to reset the fields to your previous configuration.
Click Clear to reset the fields to the default settings.
This field displays the descriptive name of a profile.
This field displays whether the profile is active or not.
Click Delete to remove the selected entry from the summary table.
Click Cancel to clear the Delete check boxes.
OMC-2301 User's Guide