ICP-CC488 | User's Guide | 3.
Figure 4:
ICP-CP516 Sixteen Zone LED
Codepad
The codepad is the communications interface
between you and your alarm system. Use the
codepad to issue commands. The codepad offers
both visual and audible indications that guide you
through the general operation.
The codepad incorporates numerous indicators.
There are zone indicators used to show the condition
of each zone. Four other indicators show general
status. The following pages outline a list of situations
and the relevant indicators that are seen.
The ICP-CP516 Sixteen Zone Codepad must be used
with sixteen wireless zone systems. The sixteen zone
codepads operation and display similarly to 8 zones
codepads, but also display the zones 9 through 16.
3.1

Zone Indicators

The zone indicators (1 to 8) display
1 2 3 ....
the status of the zones. Table 2 lists the
various circumstances that the
indicators display (such as Zone
Sealed, Zone Unsealed, and so on).
Table 2:
Zone Indicators
Indicator
On
Off
Flashing Fast
(0.25 sec on/
0.25 sec off)
Flashing Slow
(1 sec on/
1 sec off)
Bosch Security Systems, Inc. | 12/08 | F01U089456-02
Codepad Indicators
Definition
Zone is unsealed.
Zone is sealed.
Zone is in alarm condition.
Zone is manually isolated or
selected to be isolated.
3.2

AWAY Indicator

The AWAY indicator displays that the
system is armed in AWAY Mode. The
AWAY indicator flashes in unison with
the STAY indicator when
programming various options
throughout the Operators Manual.
Refer to Section 3.10.2 Arming in AWAY
Mode for information on the different
methods of arming the system in
AWAY Mode.
Table 3:
AWAY Indicator
Indicator
Definition
On
System is armed in AWAY Mode.
Off
System is not armed in AWAY Mode.
3.3

STAY Indicator

The STAY indicator displays that the
system is armed in STAY Mode 1 or
STAY Mode 2. The STAY indicator also
flashes in unison with the AWAY
indicator when programming various
options throughout the Operators Manual.
Refer to Section 3.10.3 Arming in STAY
Mode 1 for different methods of arming in
STAY Mode 1. Refer to Section 3.10.4
Arming in STAY Mode 2 for the method of
arming in STAY Mode 2.
Table 4:
STAY Indicator
Indicator
Definition
On
System is armed in STAY Mode 1
or STAY Mode 2.
Off
System is not armed in STAY
Mode 1 or STAY Mode 2.
Flashing
Zone isolating mode or setting
twice a sec
STAY Mode 2 zones.
Flashing once
Day alarm status – day alarm
every
turned on.
3 sec
3.4

System Disarmed

This indicator displays with the
indicator when the system is disarmed.
3.5

MAINS Indicator

The MAINS indicator displays that the
system's AC MAINS supply is normal or
failed.
EN | 6