ICP-CC488 | User's Guide | 21.
1. Enter your four character Master Code, followed
by the [2] and [#] keys (for example, [25802#]).
Two beeps sound and the STAY and AWAY
indicators flash.
2. Press the [*] key followed by the [4] and [#] keys
(for example, [*4#]).
The STAY and AWAY indicators are disabled.
21.

Basic Pager Reporting

This feature only applies if your system reports to a
pocket pager. Basic pager reporting requires some
interpretation of the numbers appearing on the
display. It is possible to differentiate between 1000
different systems when a number of control panels
report to one pocket pager.
The Pager format supports only eight
zones.
21.1

Basic Pager Display Information

Subscriber ID Number
This is the identification number of the control panel,
which can only be programmed by your installer.
Zone Status
The zone status display shows the status of each zone
(1 to 8). Table 14 on page 18 describes the meaning
of each number when it appears on the zone status
display.

Table 14: Zone Status Display Descriptions

Number
Zone
Displayed
Description
0
Zone Normal
Indicates that the corresponding zone is in
the sealed state.
1
Alarm
Indicates that the corresponding zone is
unsealed and in alarm condition.
2
Zone Bypassed
Indicates that a system operator manually
isolated the corresponding zone. Refer to
Section 8. Isolating Zones 11 for
information on how to manually isolate a
zone(s) prior to arming the system.
3
Zone Trouble
Indicates that a zone was left unsealed
after the end of Exit Time.
Bosch Security Systems, Inc. | 12/08 | F01U089456-02
Basic Pager Reporting
System Status
The system status information is divided into four
digits.

Table 15: System Status

System Status
Display
First digit
Second digit
Third digit
Fourth digit
Figure 9 on page 19 shows that the transmission came
from the control panel with ID number 5678, and
that zone 2 is in alarm. The figure also shows that
zone 3 was manually isolated and the system armed.
Description
Indicates whether the system is
armed or disarmed:
8 = Disarmed
9 = Armed
Indicates which codepad alarm was
activated by the operator:
0 = No Codepad Alarm
1 = Codepad Panic or Duress Alarm
2 = Codepad Fire Alarm
3 = Codepad Medical Alarm
Indicates when the AC MAINS supply
fails:
0 = AC Supply is normal
1 = AC Supply has failed
Indicates when a system fault occurs
at the control panel:
0 = System Normal – There are no
faults
1 = System Fault – There is a fault
registered by the control panel
EN | 18