Figure 24: Standalone System - Bosch K2200 Series User Manual

Readykey controllers
Table of Contents

Advertisement

K2200 Series | User Guide | 7.0
Figure 22: Standalone System
Key doesn't open door
Printer connected?
Yes
Read transaction
generated
No Access:
Level
Key not allowed
access through door -
see System
Supervisor
Key locked out - no
access through any
door - see System
Bosch Security Systems | 7/03 | 17376 v1.1 / 47491C
Troubleshooting
No
LED Activity?
Yes
LED green?
Yes
Hardware fault -
contact Installer
No
Contact System Supervisor -
variety of possibilities to check
(same as for when printout
available) - No Access:Level; No
Access: Locked Out; etc
No Access:
No Access:
No Entry/Exit:
Locked Out
Time
Passback
Key on Time Profile - no
access at current time -
see System Supervisor
Locked in / out due to
passback - see System
Supervisor
Supervisor
No
Try MASTER key
Yes
LED activity?
No
Yes
LED green?
Yes
Door Opening?
No
Yes
Key Faulty
Access
Incorrect PIN
Authorised
Wrong PIN entered -
Enter correct PIN
System allows access.
Door not opening due to
hardware fault -, call
Installer
EN | 52
Hardware fault -
contact Installer
No
No Access:
Unknown ID
Key not in the
system

Advertisement

Table of Contents