120V Wiring Diagram - Da-Lite Executive Electrol Instruction Book

Hide thumbs Also See for Executive Electrol:
Table of Contents

Advertisement

EXECUTIVE ELECTROL
®

120V WIRING DIAGRAM

CAPACITOR
INTERNAL
WIRING
EXTERNAL WIRING
TO BE COMPLETED
BY INSTALLER
DOWN
INSTALLATION
BLACK
BLUE
RED (UP)
BLACK
WHITE
BLACK
BLACK
(DOWN)
RED
GREEN
(GROUND)
BLACK WITH YELLOW
UP
AC COMMON
OFF
AC HOT
120V.AC 60HZ.
1 AMP . MAX
SIDE VIEW OF
SWITCH & BOX
THIS SWITCH CANNOT BE USED WITH L.V.C.
240 VOLT WIRING DIAGRAM
FOR STANDARD WALL SWITCH:
Da-Lite offers two styles of 240 volt wall
switches for standard operation. Please
see wiring diagram included in wall
switch box included with screen.
DOWN LIMIT SWITCH
SOLENOID SWITCH
MOTOR: 120V.60 CYCLES 1/10 HP INTERMITTENT
DUTY WITH AUTO-RESET THERMAL PROTECTOR
DOWN
ADJ.
BLUE
SOLENOID
WHITE
UP LIMIT SWITCH
(OPERATED BY DOOR)
JUNCTION BOX MOUNTED IN
SCREEN CASE, IN WHICH INTERNAL
WIRING TERMINATES IN
WHITE, BLACK AND RED LEADS
IN MULTIPLE CONTROL INSTALLATIONS THIS SWITCH IS
REPLACED BY THE LOW VOLTAGE CONTROL, OPERATED
FROM PUSH-BUTTON STATIONS
OPERATING SWITCH,
SWITCH BOX, AND
PLATE FURNISHED
WITH SCREEN. (SPDT)
WITH CENTER OFF)