120V Wiring Diagram

Internal wiring has been completed at the factory. Installer must route power to the wall switch and to the junction box located on the left end of
the screen case.
See wiring diagram below for wire connections.
NOTE: This screen can only be controlled by a single 120VAC wall switch. To use multiple switches, an optional low voltage control must be
used.
120V Wiring Diagram
For Standard Wall Switch
Junction Box
Located In Left Endcap
NOTE: A single switch cannot be used
to operate more than one screen.
Contact the factory for further
information.
SPDT Switch with
Center Off
Up
Off
Down
This Switch Can Not
be used with LVC.
4
AC (Common)
Black
AC Hot 120VAC 60HZ
Black/Yellow
Red
White
White
Red
Black
Green
Motor