Removing/Installing The Batteries - Invacare Pronto M41 Owner's Manual

With surestep
Hide thumbs Also See for Pronto M41:
Table of Contents

Advertisement

Batteries with terminal configuration as shown below MUST be used. Batteries that
have the reverse terminal configuration MUST NOT be used - otherwise injury and
damage may occur.
USE THIS CONFIGURATION
U1 Battery
POSITIVE (+) Battery Terminal
NOTE: Recommended battery type is spill proof and requires no maintenance except routine 
charging.
NOTE: Charge batteries daily. DO NOT allow batteries to completely discharge. To charge 
batteries, refer to Charging Batteries on page 63.
NOTE: Invacare recommends that both batteries be replaced if one battery is defective.

Removing/Installing the Batteries

NOTE: For this procedure, refer to FIGURE 13.1 on page 60.
Install protective caps on POSITIVE (+) and NEGATIVE (-) terminals.
All battery terminal covers (two on the right battery and two on the left battery)
MUST be installed prior to use.
Removing
1. Disconnect the joystick. Refer to Disconnecting/Connecting the Joystick on page 57.
2. Remove the seat. Refer to Removing/Installing the Seat Assembly on page 38.
3. Remove the top shroud. Refer to Removing/Installing the Top Shroud on page 50.
4. Disconnect the right battery from the controller (BLACK connector). 
Part No. 1143206
WARNING
NEGATIVE (-)
U1 Battery
Battery Terminal
NEGATIVE (-)
Battery Terminal
WARNING
59
SECTION 13—BATTERIES
DO NOT USE
POSITIVE (+)
Battery Terminal
Pronto® M41 with SureStep®

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents