Gathering Failure Information (Overview) - HP Integrity Superdome 2 16-socket Service Manual

Hp integrity superdome 2 user service guide
Hide thumbs Also See for Integrity Superdome 2 16-socket:
Table of Contents

Advertisement

Gathering failure information (overview)

To obtain information about failures recorded by the system, use the following commands:
Show cae
sd-oa1> show cae -L
Sl.No Severity
################################################################################
71
Critical
temperatur...
70
Critical
temperatur...
show CAE
Use show CAE
oa1> show cae -E -n 70
Alert Number : 70
Event Identification :
Event ID : 3040
Provider Name : CPTIndicationProvider
Event Time : Fri May 18 04:56:22 2012
Indication Identifier : 8304020120518045622
Managed Entity :
OA Name : sd-oa1
System Type : 59
System Serial No. : USExxxxxS
OA IP Address : aa.bb.cc.dd
Affected Domain :
Enclosure Name : lc-sd2
RackName : sd2
RackUID : 02SGHxxxxAVY
Impacted Domain : Complex
Complex Name : SD2
Partition ID : Not Applicable
Summary :
XFM air intake or exhaust temperature is too hot
Full Description :
The air temperature measured at one of the XFM air intakes or exhausts is too hot to allow normal
operation.
generation.
hardware damage.
Probable Cause 1 :
Data center air conditioning is not functioning properly
Recommended Action 1 :
Fix the air conditioning problem
Probable Cause 2 :
The system air intake is blocked
Recommended Action 2 :
Check and unblock air intakes
Replaceable Unit(s) :
Part Manufacturer : HP
Spare Part No. : AH341-67001
Part Serial No. : MYJaaaaaWV
Part Location : 0x0100ff02ff00ff51
Additional Info : Not Applicable
Additional Data :
Severity : Critical
Alert Type : Environmental Alert
Event Category : System Cooling
54
Troubleshooting
Power
Device Failure
Device Degraded
L (within HR, run show HR to enter the HR submenu)
EventId EventCategory PartitionId
3040
System Coo... N/A
3040
System Coo... N/A
E -n <CAE-ID>
E -n <CAE-ID> to obtain more details about specific events.
Measures are being taken to increase the cooling ability of the box, and to reduce heat
If the temperature continues to increase, however, partitions may be shut down to prevent
OK
OK
OK
EventTime
Fri May 18 06:26:34 2012
Fri May 18 04:56:22 2012
enclosure1/xfm2
Summary
XFM air intake or exhaust
XFM air intake or exhaust