When the enclosure UID LED is off, the Insight Display is illuminated amber when any error condition
exists. The navigation bar displays the following selections when an error condition exists:
Health summary icon— Displays the Health Summary screen
Fix This— Suggests corrective action to clear the current error
Next Alert— Displays the next alert, or if none exist, displays the Health Summary screen
Previous Alert— Displays the previous alert

Power errors

Power errors can occur because of insufficient power to bring up an enclosure. Power errors can
occur on server blades, storage blades, or interconnect modules.
To correct a power error:
1.
Use the arrow buttons to navigate to Fix This, and press OK.
2.
Review and complete the corrective action suggested by the Insight Display. In most cases,
you must either add power supplies to the enclosure or remove the indicated components.

Cooling errors

Cooling errors occur when too few fans are installed in the enclosure or when the existing fans
are not installed in an effective configuration. Cooling errors can occur on server blades, storage
blades, or interconnect modules.
To correct a cooling error:
1.
Use the arrow buttons to navigate to Fix This, and press OK.
2.
Review and complete the corrective action suggested by the Insight Display. In most cases,
you must either add fans to the enclosure, correct the fan configuration, or remove the indicated
components.

Location errors

Location (installation) errors occur when the component is not installed in the appropriate bay.
Location errors can occur on server blades, storage blades, power supplies, and fans.
To correct a location error:
1.
Use the arrow buttons to navigate to Fix This, and press OK.
2.
Review and complete the corrective action suggested by the Insight Display. Remove the
indicated component, and install it into the correct bay. The Insight Display will indicate the
correct bay number.

Configuration errors

Configuration errors can occur if the interconnect modules are installed in the wrong bays or if
mezzanine cards are installed in the wrong connectors in the server blade. Configuration errors
can occur on server blades and interconnect modules.
To correct a configuration error:
1.
Use the arrow buttons to navigate to Fix This, and press OK.
2.
Review and complete the corrective action suggested by the Insight Display. Depending on
the error received, do one of the following:
Remove the indicated interconnect module and install it into the correct bay (the Insight
Display indicates the correct bay).
Remove the server blade to correct the mezzanine card installation (the Insight Display
will indicate the correct bay). For information on installing the mezzanine card, see the
server-specific user guide on the Documentation CD.