C ISR 9096 Interconnect Specifications

The technical specifications of the ISR 9096 are as follows:
Feature
Chassis Architecture
Line Board
Fabric Board
Management Board
Interconnect Switching
Specifications
Specification
• Four slots, each of which can accommodate one line board or one router blade drawer
(hosting up to 3 router blades).
• Redundant power supplies.
• Redundant fan trays.
• Redundant management blades.
• 24, auto-sensing 1x/4x InfiniBand ports (2.5/10 Gb/s)
• Alternative 1:8 12X InfiniBand ports (30 Gb/s)
• Alternative 2:4 12X and 12 4X InfiniBand ports
• Connectors: 8-pair MicroGigaCN / LANELINK F CONN
• Indicators: Physical connectivity and logical connectivity LEDs per port, power and
info LEDs
• Hot-pluggable Media Converter for single optical cable.
• One to four per system
• Indicators:
— Physical connectivity and logical connectivity LEDs per Line Board link port
— Power
— Info LEDs
— Hot-swap LEDs
• VoltaireVision including:
— Fabric Management
— Chassis and Device Management
— Network Traffic Management
— Storage Resource Management
• InfiniBand managers
• InfiniBand Agents
• Supported management protocols:
— SNMPv2c
— Telnet
— SSH
— HTTP
— FTP
— IBTA
— SMI/GSI
• Connectors:
— RS232 DB9-M,
— I²C DB9-F
• Indicators:
— Power
— Subnet manager active
— Chassis manager active
— Info LEDs
— Hot-swap LEDs
• 1.92 Tb/sec port-to-port data throughput
• 420 nanoseconds latency (max.)
• 8 Data Virtual Lanes
• 1 Management Virtual Lanes
• MTU 4096 Bytes, max